Consequences of an imperfectly mounted reinforcement cage in a generical cylindrical concrete container during mechanical specimen tests

  • By highest court decision in 2007 the issued license for the Konrad repository (a former iron ore mine) for low and intermediate level radioactive waste was finally confirmed. Since then, the site is improved, prepared and equipped for the currently planned start of waste package emplacement by 2029. The Bundesanstalt fuer Materialforschung und -pruefung (BAM, Federal Institute for Materials Research and Testing) is regularly contracted by the Bundesgesellschaft für Endlagerung (BGE, Federal Company for Radioactive Waste Disposal) as the responsible authority for waste product control, waste container design testing, and waste package acceptance. In this context BAM is mainly responsible for design testing of various container types including the evaluation quality assurance measures for container manufacturing. In the written Konrad disposal requirements all acceptance criteria for potential final disposal containers are defined. In addition to general requirements concerningBy highest court decision in 2007 the issued license for the Konrad repository (a former iron ore mine) for low and intermediate level radioactive waste was finally confirmed. Since then, the site is improved, prepared and equipped for the currently planned start of waste package emplacement by 2029. The Bundesanstalt fuer Materialforschung und -pruefung (BAM, Federal Institute for Materials Research and Testing) is regularly contracted by the Bundesgesellschaft für Endlagerung (BGE, Federal Company for Radioactive Waste Disposal) as the responsible authority for waste product control, waste container design testing, and waste package acceptance. In this context BAM is mainly responsible for design testing of various container types including the evaluation quality assurance measures for container manufacturing. In the written Konrad disposal requirements all acceptance criteria for potential final disposal containers are defined. In addition to general requirements concerning container design, materials, dimensions and others, specific mechanical load scenarios the casks have to withstand are derived from an analysis of the on-site handling and emplacement procedures. Drop tests from different heights under consideration of the most damaging drop orientation and a stacking test are two examples for safety demonstrations that have to be performed during the container design testing procedure to qualify the respective container type. The containers, whether cubic or cylindrical containers, can be made from different materials like ductile cast iron, reinforced concrete or as welded construction from steel plates and profiles. In case of concrete containers the reinforcement has the function to absorb tensile forces the concrete is not able to withstand by its own. Because of manufacturing imperfections of cylindrical concrete waste containers manufactured already decades ago, the reinforcement cages are not always exactly, axisymmetrically positioned when they were poured. This inspired BAM to perform various ABAQUS finite-element (FE) simulations by using the example of a simplified cylindrical container design with generic dimensions and pure elastic material properties. As outcome the stress conditions in the container during the drop test impact under different drop positions and during the stacking test were investigated and are explained and illustrated in this contribution. Different reinforcement cage positions were calculated and compared. On the basis of the calculated tensile and compressive stress distributions suggestions are derived on how a cylindrical concrete container with an imperfectly placed reinforcement cage has to be oriented for a drop or stacking test to ensure the most damaging test scenario.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • PVP2024_123797_Mike_Weber_Final_Paper_240410.pdf
    eng

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Mike Weber, Holger Völzke, Gregor Nieslony
Dokumenttyp:Beitrag zu einem Tagungsband
Veröffentlichungsform:Graue Literatur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Conference Proceedings ASME 2024 Pressure Vessels & Piping Conference
Jahr der Erstveröffentlichung:2024
Organisationseinheit der BAM:3 Gefahrgutumschließungen; Energiespeicher
3 Gefahrgutumschließungen; Energiespeicher / 3.4 Sicherheit von Lagerbehältern
Verlag:ASME
Verlagsort:New York City, USA
Jahrgang/Band:5
Erste Seite:1
Letzte Seite:8
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Angewandte Physik
Freie Schlagwörter:Container design testing procedure; Drop test; Finite-element-analysis; Imperfectly mounted reinforcement cage; Reinforced concrete containers; Stacking test
Themenfelder/Aktivitätsfelder der BAM:Energie
Energie / Kerntechnische Entsorgung
Veranstaltung:ASME 2024 Pressure Vessels & Piping Conference
Veranstaltungsort:Bellevue, Washington, USA
Beginndatum der Veranstaltung:28.07.2024
Enddatum der Veranstaltung:02.08.2024
DOI:10.1115/PVP2024-123797
ISBN:978-0-7918-8851-3
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:19.02.2025
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:26.05.2025
Einverstanden