Distinction of tendon ducts and rebars by GPR reflection signal patterns

  • We investigated the possibility of surrounding waves along with perimeter of large diameter tendon ducts during ground penetrating radar (GPR) testing of concrete structures. The surrounding waves influence the primary reflection from tendon duct and alter the phase as well as amplitude of signal depending on the diameter of the tendon duct. This phenomenon was studied in detail by conducting several simulations using a commercial software Reflexw®. Finite Difference Time Domain method was adopted to analyze reflection patterns from objects of various diameters located at different depths in concrete media. The proposed methodology will be useful in qualitative assessment of size of metallic objects greater than a diameter of 6 cm. In general, the identification of large diameter tendon ducts in a civil structure is carried out by prior knowledge of the civil plan and its diagonal appearance to smaller diameter object mesh. The proposed methodology will enhance theWe investigated the possibility of surrounding waves along with perimeter of large diameter tendon ducts during ground penetrating radar (GPR) testing of concrete structures. The surrounding waves influence the primary reflection from tendon duct and alter the phase as well as amplitude of signal depending on the diameter of the tendon duct. This phenomenon was studied in detail by conducting several simulations using a commercial software Reflexw®. Finite Difference Time Domain method was adopted to analyze reflection patterns from objects of various diameters located at different depths in concrete media. The proposed methodology will be useful in qualitative assessment of size of metallic objects greater than a diameter of 6 cm. In general, the identification of large diameter tendon ducts in a civil structure is carried out by prior knowledge of the civil plan and its diagonal appearance to smaller diameter object mesh. The proposed methodology will enhance the confidence in identification of the larger diameter tendon ducts even if the civil plan is not known accurately.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • GPR 2018 - Govind K. Sharma and Thomas Kind_from_Proceedings.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Govind Sharma, Thomas Kind
Dokumenttyp:Beitrag zu einem Tagungsband
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Proceedings - 2018 17th International Conference on Ground Penetrating Radar
Jahr der Erstveröffentlichung:2018
Organisationseinheit der BAM:8 Zerstörungsfreie Prüfung
8 Zerstörungsfreie Prüfung / 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen
Erste Seite:232
Letzte Seite:235
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurbau
Freie Schlagwörter:Concrete; Ground penetrating radar; Rebar
Themenfelder/Aktivitätsfelder der BAM:Chemie und Prozesstechnik
Infrastruktur
Veranstaltung:17th International Conference on Ground Penetrating Radar
Veranstaltungsort:Rapperswil, Switzerland
Beginndatum der Veranstaltung:18.06.2018
Enddatum der Veranstaltung:21.06.2018
ISBN:978-1-5386-5776-8
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:15.10.2018
Referierte Publikation:Nein