Multimodal cleavable reporters versus conventional labels for optical quantification of accessible amino and carboxy groups on nano- and microparticles

  • Many applications of nanometer- and micrometer-sized particles include their surface functionalization with linkers, sensor molecules, and analyte recognition moieties like (bio)ligands. This requires knowledge of the chemical nature and number of surface groups accessible for subsequent coupling reactions. Particularly attractive for the quantification of these groups are spectrophotometric and fluorometric assays, which can be read out with simple instrumentation. In this respect, we present here a novel Family of cleavable spectrophotometric and multimodal reporters for conjugatable amino and carboxyl surface groups on nano- and microparticles. This allows determination of particle-bound labels, unbound reporters in the supernatant, and reporters cleaved off from the particle surface, as well as the remaining thiol groups on particle, by spectrophotometry and inductively coupled optical emission spectrometry (32S ICP-OES). Comparison of the performance of these cleavable reportersMany applications of nanometer- and micrometer-sized particles include their surface functionalization with linkers, sensor molecules, and analyte recognition moieties like (bio)ligands. This requires knowledge of the chemical nature and number of surface groups accessible for subsequent coupling reactions. Particularly attractive for the quantification of these groups are spectrophotometric and fluorometric assays, which can be read out with simple instrumentation. In this respect, we present here a novel Family of cleavable spectrophotometric and multimodal reporters for conjugatable amino and carboxyl surface groups on nano- and microparticles. This allows determination of particle-bound labels, unbound reporters in the supernatant, and reporters cleaved off from the particle surface, as well as the remaining thiol groups on particle, by spectrophotometry and inductively coupled optical emission spectrometry (32S ICP-OES). Comparison of the performance of these cleavable reporters with conductometry and conventional labels, utilizing changes in intensity or Color of absorption or emission, underlines the analytical potential of this versatile concept which elegantly circumvents Signal distortions by scattering and Encoding dyes and enables straightforward validation by method comparison.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • MM_NN_MS 2018.pdf
    eng
  • MM_NN_SI 2018.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Marko Moser, Nithiya Nirmalananthan-Budau, Thomas Behnke, Daniel GeißlerORCiD, Ute Resch-GengerORCiD
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Analytical chemistry
Jahr der Erstveröffentlichung:2018
Organisationseinheit der BAM:1 Analytische Chemie; Referenzmaterialien
1 Analytische Chemie; Referenzmaterialien / 1.2 Biophotonik
Verlag:ACS Publ.
Verlagsort:Washington, DC
Jahrgang/Band:90
Ausgabe/Heft:9
Erste Seite:5887
Letzte Seite:5895
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Freie Schlagwörter:Cleavable reporter; Optical quantification; Polymer particles; Validation
Themenfelder/Aktivitätsfelder der BAM:Chemie und Prozesstechnik
DOI:10.1021/acs.analchem.8b00666
ISSN:1520-6882
ISSN:0003-2700
Bemerkung:
Geburtsname von Nirmalananthan-Budau, Nithiya: Nirmalananthan, N. -  Birth name of Nirmalananthan-Budau, Nithiya: Nirmalananthan, N.
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:04.05.2018
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:04.05.2018
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.