Thickness determination of semitransparent solids using flash thermography and an analytical model
- As groundwork for thickness determination of polymeric surface protection systems for concrete, we present a method for measuring the thickness of isolated semitransparent solids using flash thermography both in transmission and reflection configuration. Since standard models do not capture semitransparency, an advanced analytical model by Salazar et al. is applied. Physical material parameters are deduced by fitting experimental data from samples of well-known thickness. Using those, the thickness of samples of the material can be obtained by fitting, as demonstrated for different semitransparent polymer materials.
Autor*innen: | Simon AltenburgORCiD, H. Weber, Rainer KrankenhagenORCiD |
---|---|
Dokumenttyp: | Zeitschriftenartikel |
Veröffentlichungsform: | Verlagsliteratur |
Sprache: | Englisch |
Titel des übergeordneten Werkes (Englisch): | Quantitative InfraRed Thermography Journal |
Jahr der Erstveröffentlichung: | 2017 |
Verlag: | Taylor and Francis |
Verlagsort: | Abingdon, UK |
Jahrgang/Band: | 15 |
Ausgabe/Heft: | 1 |
Erste Seite: | 95 |
Letzte Seite: | 105 |
DDC-Klassifikation: | Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurbau |
Freie Schlagwörter: | Analytical model; Concrete; Semitransparency; Surface protection; Thermography; Thickness |
DOI: | 10.1080/17686733.2017.1331655 |
ISSN: | 1768-6733 |
ISSN: | 2116-7176 |
Verfügbarkeit des Dokuments: | Datei im Netzwerk der BAM verfügbar ("Closed Access") |
Datum der Freischaltung: | 12.06.2017 |
Referierte Publikation: | Ja |
Datum der Eintragung als referierte Publikation: | 12.04.2018 |