Testing of pressurized vessels
- The results are based on data1. Figure 3 displays temperatures of the tank wall and of the gas phase over testing time. It can be seen that a complete coating strongly delayed the heating of tank wall and gas phase, whereas the partly coated tanks only had a minor influence on temperature development. There was no significant difference between a half coated and a thirdly coated tank measurable. Figure 4 shows the internal pressure of tanks over testing time. Only the fully coated tank enabled a low pressure over 90 min testing time. Hence, a complete coating is necessary to guarantee the fire safety of hazmat tanks and a partly coating is not sufficient.
| Autor*innen: | Frank Otremba |
|---|---|
| Koautor*innen: | Christian Sklorz |
| Dokumenttyp: | Posterpräsentation |
| Veröffentlichungsform: | Präsentation |
| Sprache: | Englisch |
| Jahr der Erstveröffentlichung: | 2017 |
| DDC-Klassifikation: | Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurwissenschaften und zugeordnete Tätigkeiten |
| Freie Schlagwörter: | Dangerous goods; Fire; Testing; Vessels |
| Veranstaltung: | Annual Conference on Engineering and Information Technology |
| Veranstaltungsort: | Nagoya - Japan |
| Beginndatum der Veranstaltung: | 29.03.2017 |
| Enddatum der Veranstaltung: | 31.03.2017 |
| Verfügbarkeit des Dokuments: | Datei im Netzwerk der BAM verfügbar ("Closed Access") |
| Datum der Freischaltung: | 13.04.2017 |
| Referierte Publikation: | Nein |