Zitieren Sie bitte immer diesen URN: urn:nbn:de:kobv:b43-397053

A facile method to probe the vascular permeability of nanoparticles in nanomedicine applications

  • The effectiveness of nanoparticles (NP) in nanomedicine depends on their ability to extravasate from vasculature towards the target tissue. This is determined by their permeability across the endothelial barrier. Unfortunately, a quantitative study of the diffusion permeability coefficients (Pd) of NPs is difficult with in vivo models. Here, we utilize a relevant model of vascular-tissue interface with tunable endothelial permeability in vitro based on microfluidics. Human umbilical vein endothelial cells (HUVECs) grown in microfluidic devices were treated with Angiopoietin 1 and cyclic adenosine monophosphate (cAMP) to vary the Pd of the HUVECs monolayer towards fluorescent polystyrene NPs (pNPs) of different sizes, which was determined from image analysis of their fluorescence intensity when diffusing across the monolayer. Using 70 kDa dextran as a probe, untreated HUVECs yielded a Pd that approximated tumor vasculature while HUVECs treated with 25 μg/mL cAMP had Pd that approximatedThe effectiveness of nanoparticles (NP) in nanomedicine depends on their ability to extravasate from vasculature towards the target tissue. This is determined by their permeability across the endothelial barrier. Unfortunately, a quantitative study of the diffusion permeability coefficients (Pd) of NPs is difficult with in vivo models. Here, we utilize a relevant model of vascular-tissue interface with tunable endothelial permeability in vitro based on microfluidics. Human umbilical vein endothelial cells (HUVECs) grown in microfluidic devices were treated with Angiopoietin 1 and cyclic adenosine monophosphate (cAMP) to vary the Pd of the HUVECs monolayer towards fluorescent polystyrene NPs (pNPs) of different sizes, which was determined from image analysis of their fluorescence intensity when diffusing across the monolayer. Using 70 kDa dextran as a probe, untreated HUVECs yielded a Pd that approximated tumor vasculature while HUVECs treated with 25 μg/mL cAMP had Pd that approximated healthy vasculature in vivo. As the size of pNPs increased, its Pd decreased in tumor vasculature, but remained largely unchanged in healthy vasculature, demonstrating a trend similar to tumor selectivity for smaller NPs. This microfluidic model of vascular-tissue interface can be used in any laboratory to perform quantitative assessment of the tumor selectivity of nanomedicine-based systems.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Y.T. Ho, G Adriani, Sebastian Beyer, P.-T. Nhan, R. D. Kamm, J.C.Y. Kah
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Nature Scientific Reports
Jahr der Erstveröffentlichung:2017
Veröffentlichende Institution:Bundesanstalt für Materialforschung und -prüfung (BAM)
Verlag:Macmillan
Jahrgang/Band:7
Ausgabe/Heft:1
Erste Seite:Article 707, 1
Letzte Seite:13
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurwissenschaften und zugeordnete Tätigkeiten
Freie Schlagwörter:Nanoparticle
DOI:10.1038/s41598-017-00750-3
URN:urn:nbn:de:kobv:b43-397053
ISSN:2045-2322
Verfügbarkeit des Dokuments:Datei für die Öffentlichkeit verfügbar ("Open Access")
Lizenz (Deutsch):License LogoCreative Commons - Namensnennung
Datum der Freischaltung:07.04.2017
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:20.12.2017
Schriftenreihen ohne Nummerierung:Wissenschaftliche Artikel der BAM
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.