Zitieren Sie bitte immer diesen URN: urn:nbn:de:kobv:b43-396274

A collaborative engineering and archaeology project to investigate decay in historic rammed earth structures: The case of the Medieval preceptory in Ambel

  • This study assesses the structural vulnerability of part of a later medieval earthen building at Ambel (near Zaragoza, Spain), once a preceptory or monastic house belonging to the Military Orders. An inspection of its morphology and materials coupled with the results of an extensive campaign of static monitoring reveals marked structural inhomogeneities, the product of more than a thousand years of construction, failure, and repair from the 10th century to the present day. Building materials are inappropriately juxtaposed, there are discontinuities between construction phases and fundamental concerns remain over the long-term stability of the structure. The current condition of the structure is mainly influenced by structural discontinuities introduced at the time of construction, the unintended consequences of repair and modification and the material decay that has affected the base of the rammed earth walls. The overall findings of the static monitoring show that there isThis study assesses the structural vulnerability of part of a later medieval earthen building at Ambel (near Zaragoza, Spain), once a preceptory or monastic house belonging to the Military Orders. An inspection of its morphology and materials coupled with the results of an extensive campaign of static monitoring reveals marked structural inhomogeneities, the product of more than a thousand years of construction, failure, and repair from the 10th century to the present day. Building materials are inappropriately juxtaposed, there are discontinuities between construction phases and fundamental concerns remain over the long-term stability of the structure. The current condition of the structure is mainly influenced by structural discontinuities introduced at the time of construction, the unintended consequences of repair and modification and the material decay that has affected the base of the rammed earth walls. The overall findings of the static monitoring show that there is no related damage, variations in crack widths are related to the building seasonal cycle. While static analysis is an essential prerequisite before a suitable maintenance program can be fully defined, this study argues that no evaluation of the structural behavior of any historic building can afford to ignore its archaeological “biography” of modification and repair.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Miccoli et al_IJAH 2017_A Collaborative Engineering and Archaeology Project - Ambel.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Lorenzo Miccoli, C. Gerrard, C. Perrone, André Gardei, C. Ziegert
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):International Journal of Architectural Heritage
Jahr der Erstveröffentlichung:2017
Verlag:Taylor & Francis Group
Jahrgang/Band:11
Ausgabe/Heft:5
Erste Seite:636
Letzte Seite:655
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurwissenschaften und zugeordnete Tätigkeiten
Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Sanitär- und Kommunaltechnik; Umwelttechnik
Freie Schlagwörter:Archaeology; Historical earthen building; Materials characterization; Rammed earth; Static monitoring
DOI:10.1080/15583058.2016.1277283
URN:urn:nbn:de:kobv:b43-396274
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:04.04.2017
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:21.08.2017
Einverstanden