Certification report for the reference materials ERM-AE102a, -AE104a, -AE120, -AE121 and -AE122
- Isotope reference materials are essential to enable reliable and comparable isotope data. Besides the correction of mass fractionation or mass discrimination isotope reference materials are indispensible for validation and quality control of analytical procedures. This article describes the production and certification of a set of five isotope reference materials ERM-AE102a, 104a, AE120, 121 and 122, for boron isotope analysis. The isotopic composition of all materials has been adjusted by mixing boron mother solutions enriched in 10B or 11B with a boron mother solution having natural-like isotopic composition under full gravimetric control. All mother solutions have been analysed for their boron mass fraction as well as their boron isotopic composition by TIMS using IDMS as calibration technique. For all five reference materials the isotopic composition obtained on the basis of the gravimetric data agrees very well with the isotopic composition obtained from different TIMS techniques.Isotope reference materials are essential to enable reliable and comparable isotope data. Besides the correction of mass fractionation or mass discrimination isotope reference materials are indispensible for validation and quality control of analytical procedures. This article describes the production and certification of a set of five isotope reference materials ERM-AE102a, 104a, AE120, 121 and 122, for boron isotope analysis. The isotopic composition of all materials has been adjusted by mixing boron mother solutions enriched in 10B or 11B with a boron mother solution having natural-like isotopic composition under full gravimetric control. All mother solutions have been analysed for their boron mass fraction as well as their boron isotopic composition by TIMS using IDMS as calibration technique. For all five reference materials the isotopic composition obtained on the basis of the gravimetric data agrees very well with the isotopic composition obtained from different TIMS techniques. Performed stability and homogeneity studies show no significant influence on the isotopic composition as well as on the related uncertainties. The certified isotope abundances for 10B are 0.29995 (27) for ERM-AE102a and 0.31488 (28) for ERM-AE104a. The certified δ11B values are -20.2 (6) ‰ for ERM-AE120, 19.9(6) ‰ for ERM-AE121 and 39.7 (6) ‰ for ERM-AE122. Together with the formerly certified ERM-AE101 and -AE103 a unique set of seven certified reference materials (CRM) for boron isotope analysis is now available from BAM.…
Autor*innen: | Jochen VoglORCiD, Dorit Becker, Maren Koenig, M. Rosner |
---|---|
Dokumenttyp: | Forschungsbericht |
Veröffentlichungsform: | Eigenverlag BAM |
Sprache: | Englisch |
Jahr der Erstveröffentlichung: | 2010 |
Veröffentlichende Institution: | Bundesanstalt für Materialforschung und -prüfung (BAM) |
Verlag: | Bundesanstalt für Materialforschung und -prüfung (BAM) |
Verlagsort: | Berlin |
Erste Seite: | 1 |
Letzte Seite: | 24 |
DDC-Klassifikation: | Naturwissenschaften und Mathematik / Chemie / Analytische Chemie |
Freie Schlagwörter: | Boron; Delta value; ICPMS; Isotope ratio; TIMS |
URN: | urn:nbn:de:kobv:b43-355813 |
Verfügbarkeit des Dokuments: | Datei für die Öffentlichkeit verfügbar ("Open Access") |
Lizenz (Deutsch): | Allgemeines Deutsches Urheberrecht |
Datum der Freischaltung: | 29.03.2016 |
Referierte Publikation: | Nein |
Schriftenreihen ohne Nummerierung: | BAM Forschungsberichte ohne Nummerierung |