Defining a reduced volume zone for the simulation of burst test on composite pressure vessels
- The developed model uses a Monte-Carlo simulation to evaluate the accumulation of fibre breaks on composite structures. As the micromechanical aspects affecting the accumulation process is evaluated within a particular finite element size (0.1 mm x 0.1 mm x 8 mm), the industries would not be able to use the model on a real-size structure. Therefore, the reduced volume method is used to provide the statistical information between the required number of elements and simulations.
Autor*innen: | Martinus Putra WidjajaORCiD |
---|---|
Koautor*innen: | S. Joannes, A. Bunsell, Georg MairORCiD, A. Thionnet |
Dokumenttyp: | Vortrag |
Veröffentlichungsform: | Präsentation |
Sprache: | Englisch |
Jahr der Erstveröffentlichung: | 2018 |
Organisationseinheit der BAM: | 3 Gefahrgutumschließungen; Energiespeicher |
3 Gefahrgutumschließungen; Energiespeicher / 3.0 Abteilungsleitung und andere | |
DDC-Klassifikation: | Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Angewandte Physik |
Freie Schlagwörter: | Composite structures; Finite element method; Pressure vessels; Reduced volume method |
Themenfelder/Aktivitätsfelder der BAM: | Energie |
Energie / Elektrische Energiespeicher und -umwandlung | |
Veranstaltung: | The 8th International Conference on Structural Analysis of Advanced Materials |
Veranstaltungsort: | Tarbes, France |
Beginndatum der Veranstaltung: | 28.08.2018 |
Enddatum der Veranstaltung: | 31.08.2018 |
Verfügbarkeit des Dokuments: | Datei im Netzwerk der BAM verfügbar ("Closed Access") |
Datum der Freischaltung: | 30.07.2019 |
Referierte Publikation: | Nein |
Eingeladener Vortrag: | Nein |