GPR Dataset of Moisture Measurements on Building Floors in Laboratory and On-Site
- Related work Laboratory Study: Combining Signal Features of Ground-Penetrating Radar to Classify Moisture Damage in Layered Building Floors https://doi.org/10.3390/app11198820 On-Site Study: TBA Doctoral Thesis: Non-destructive classification of moisture deterioration in layered building floors using ground penetrating radar https://doi.org/10.14279/depositonce-19306 Measurement Parameters The GPR measurements were carried out with the SIR 20 from GSSI and a 2 GHz antenna pair (bandwidth 1 GHz to 3 GHz) in common-offset configuration. Each B-Scan consists of N A-Scans, each including 512 samples of a 11 ns time window. Survey lines were recorded with 250 A-Scans/ meter, which equals a 4 mm spacing between each A-Scan No Gains were applied. Folder Description: Lab_dry, Lab_insulDamage, Lab_screedDamage - each contain 168 Measurements (B-Scans) in .csv on 84 dry floors, floors with insulation damage and screed damage. - each floor setup was measured twice onRelated work Laboratory Study: Combining Signal Features of Ground-Penetrating Radar to Classify Moisture Damage in Layered Building Floors https://doi.org/10.3390/app11198820 On-Site Study: TBA Doctoral Thesis: Non-destructive classification of moisture deterioration in layered building floors using ground penetrating radar https://doi.org/10.14279/depositonce-19306 Measurement Parameters The GPR measurements were carried out with the SIR 20 from GSSI and a 2 GHz antenna pair (bandwidth 1 GHz to 3 GHz) in common-offset configuration. Each B-Scan consists of N A-Scans, each including 512 samples of a 11 ns time window. Survey lines were recorded with 250 A-Scans/ meter, which equals a 4 mm spacing between each A-Scan No Gains were applied. Folder Description: Lab_dry, Lab_insulDamage, Lab_screedDamage - each contain 168 Measurements (B-Scans) in .csv on 84 dry floors, floors with insulation damage and screed damage. - each floor setup was measured twice on two orthogonal survey lines, indicated by _Line1_ and _Line2_ in the file name. - the file names encode the building floor setup e.g. CT50XP100 describes a 50 mm cement screed with 100 mm extruded polystyrene below - the material codes are CT: cement screed, CA: anhydrite screed, EP: expanded polystyrene, XP: extruded polystyrene, GW: glass wool, PS: perlites further information can be found in the publication https://doi.org/10.3390/app11198820 OnSite_ - 5 folders containing B-Scans on 5 different practical moisture damages - the building floor setup is encoded according to the lab with an additional measurement point numbering at the start and a damage case annotation at the end of the file name with _dry, _insulationDamage and_screedDamage File Description: B-Scans, Measurement files - no header - dimension: 512 x N data point with N beeing the number of A-Scans including 512 samples of a 11 ns time window. - survey lines were recorded with 250 A-Scans/ meter, which equals a 4 mm spacing between each A-Scan Moisture References - Moist_Reference of On-Site Locations include the columns MeasPoint: Measurement point, wt%Screed: moisture content of screed layer in mass percent; wt%Insul: moisture content of insulation layer in mass percent. References were obtained by drilling cores with 68 mm diameter in the center of each survey line. - Moist_Reference_Screed of Lab data include the columns Screed: Screed material and thickness in mm, wt%Screed moisture content of screed layer in mass percent - Moist Reference_Insul of Lab data include the columns Insulation: Insulation material and thickness in mm, water addition in l: water added to the insulation layer in liters, V%Insulation: water added to the insulation layer in volume percent, RH%: resulting relative humidy in the insulation layer during measurement. These References are only avaible for Lab measurements on insulation damages.…
Autor*innen: | Tim Klewe, Christoph Strangfeld, Tobias Ritzer, Sabine Kruschwitz |
---|---|
Dokumenttyp: | Forschungsdatensatz |
Veröffentlichungsform: | Graue Literatur |
Sprache: | Englisch |
Jahr der Erstveröffentlichung: | 2024 |
Organisationseinheit der BAM: | 8 Zerstörungsfreie Prüfung |
8 Zerstörungsfreie Prüfung / 8.0 Abteilungsleitung und andere | |
Herausgeber (Institution): | Bundesanstalt für Materialforschung und -prüfung (BAM) |
Verlag: | Zenodo |
Verlagsort: | Geneva |
DDC-Klassifikation: | Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Sanitär- und Kommunaltechnik; Umwelttechnik |
Freie Schlagwörter: | Building Floors; GPR; Laboratory; Material Moisture; On-Site |
Themenfelder/Aktivitätsfelder der BAM: | Umwelt |
Umwelt / Sensorik | |
Art der Ressource: | Datensatz |
DOI: | 10.5281/zenodo.10776684 |
Zugehöriger Identifikator: | https://nbn-resolving.org/urn:nbn:de:kobv:b43-533606 |
Verfügbarkeit des Dokuments: | Datei für die Öffentlichkeit verfügbar ("Open Access") |
Lizenz (Deutsch): | Creative Commons - CC BY - Namensnennung 4.0 International |
Datum der Freischaltung: | 14.03.2024 |
Referierte Publikation: | Nein |
Schriftenreihen ohne Nummerierung: | Forschungsdatensätze der BAM |