• Treffer 2 von 2
Zurück zur Trefferliste

Characterization of statistical EO-PO copolymers containing different end groups by UPLC/ESI-MS

  • Commercial statistical ethylene oxide (EO) and propylene oxide (PO) copolymers of different monomer compositions and different average molar masses were studied by liquid chromatography under critical conditions (LCCC). Theoretical predictions of the existence of a critical adsorption point (CPA) for statistical copolymers with a given chemical and sequence distribution, could be studied and confirmed. An improved way to determine these critical conditions in a copolymer, alongside the inevitable chemical composition distribution (CCD), with the aid of mass spectrometric detection is described. Shift of the critical eluent composition with the monomer composition of the polymers could be observed. Due to the relatively low average molecular weight, broad molecular weight distribution (MWD) and the presumed existence of different end group functionalities as well as sequence distribution, gradient separation only by CCD was not possible. Therefore isocratic separations at the CPA ofCommercial statistical ethylene oxide (EO) and propylene oxide (PO) copolymers of different monomer compositions and different average molar masses were studied by liquid chromatography under critical conditions (LCCC). Theoretical predictions of the existence of a critical adsorption point (CPA) for statistical copolymers with a given chemical and sequence distribution, could be studied and confirmed. An improved way to determine these critical conditions in a copolymer, alongside the inevitable chemical composition distribution (CCD), with the aid of mass spectrometric detection is described. Shift of the critical eluent composition with the monomer composition of the polymers could be observed. Due to the relatively low average molecular weight, broad molecular weight distribution (MWD) and the presumed existence of different end group functionalities as well as sequence distribution, gradient separation only by CCD was not possible. Therefore isocratic separations at the CPA of definite CCD’s were applied. Although the various present distributions partly superimposed the separation process the goal of separation by end group functionality could still be achieved on the basis of the additional dimension of ESI-MS. The existence of HO-H besides the desired AllylO-H end group functionalities could be confirmed and their amount could be estimated.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Epping_Falkenhagen_GPC_SEC and Related Techniques.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Ruben EppingORCiD
Koautor*innen:Jana Falkenhagen
Dokumenttyp:Posterpräsentation
Veröffentlichungsform:Präsentation
Sprache:Englisch
Jahr der Erstveröffentlichung:2016
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurwissenschaften und zugeordnete Tätigkeiten
Freie Schlagwörter:ESI-TOF-MS; Polymers; UPLC
Veranstaltung:International Symposium GPC/SEC and Related Techniques
Veranstaltungsort:Amsterdam, The Netherlands
Beginndatum der Veranstaltung:26.09.2016
Enddatum der Veranstaltung:29.09.2016
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:04.10.2016
Referierte Publikation:Nein
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.