Classification of fireworks in metal wire cages
- Classification tests (UN 6a and 6c) of firework batteries and composite fireworks in metal wire cages were presented. The cages are intended to be used during transport to prevent the occurrence of projections in the event of a fire. However, the results of this investigation showed that, particularly in the case of articles with whistle effects packed in this way, confinement phenomena occurred that lead to mass explosions and must be considered in future classification.
Autor*innen: | Gabriele DudekORCiD |
---|---|
Koautor*innen: | Amit Agasty |
Dokumenttyp: | Vortrag |
Veröffentlichungsform: | Präsentation |
Sprache: | Englisch |
Jahr der Erstveröffentlichung: | 2023 |
Organisationseinheit der BAM: | 2 Prozess- und Anlagensicherheit |
2 Prozess- und Anlagensicherheit / 2.4 Prüfung und Bewertung von Explosivstoffen/Pyrotechnik | |
DDC-Klassifikation: | Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurwissenschaften und zugeordnete Tätigkeiten |
Freie Schlagwörter: | Feuerwerk; Lagergruppenzuordnung; Pyrotechnik; Transportklassifizierung |
Themenfelder/Aktivitätsfelder der BAM: | Material |
Veranstaltung: | International Group of experts on the explosion risks of Unstable Substances (IGUS)- Joint Meeting CIE/IGUS-EPP |
Veranstaltungsort: | Madrid, Spain |
Beginndatum der Veranstaltung: | 17.04.2023 |
Enddatum der Veranstaltung: | 18.04.2023 |
Verfügbarkeit des Dokuments: | Datei im Netzwerk der BAM verfügbar ("Closed Access") |
Datum der Freischaltung: | 02.05.2023 |
Referierte Publikation: | Nein |
Eingeladener Vortrag: | Nein |