• Treffer 1 von 1
Zurück zur Trefferliste

Methods for the calibration of fluorescence setups and measurement of photoluminescence quantum yields

  • Photoluminescence techniques are amongst the most widely used tools in the material and life sciences, with new and exciting applications continuously emerging. Advantages include their comparative ease of use, unique sensitivity, non-invasive character, and potential for multiplexing, remote sensing, and miniaturization. Generally recognized drawbacks, however, are signals, that contain unwanted wavelength- and polarization contributions from instrument-dependent effects, which are also time-dependent due to aging of instrument-components, and difficulties to measure absolute fluorescence intensities, thus rendering the use of intensity standards mandatory for quantification. Recent developments in fluorescence-based assays in clinical, pharmaceutical, biotechnological and other areas, in conjunction with the increasing need for instrument performance validation and global trends to harmonize measurements have boosted the demand for robust, easy-to-use, readily-available, reliable,Photoluminescence techniques are amongst the most widely used tools in the material and life sciences, with new and exciting applications continuously emerging. Advantages include their comparative ease of use, unique sensitivity, non-invasive character, and potential for multiplexing, remote sensing, and miniaturization. Generally recognized drawbacks, however, are signals, that contain unwanted wavelength- and polarization contributions from instrument-dependent effects, which are also time-dependent due to aging of instrument-components, and difficulties to measure absolute fluorescence intensities, thus rendering the use of intensity standards mandatory for quantification. Recent developments in fluorescence-based assays in clinical, pharmaceutical, biotechnological and other areas, in conjunction with the increasing need for instrument performance validation and global trends to harmonize measurements have boosted the demand for robust, easy-to-use, readily-available, reliable, and well documented fluorescence standards. This includes e.g. fluorescence standards for the consideration of instrument-specific spectral and intensity distortions of measured signals and instrument performance validation as well as fluorescence intensity standards for the quantification from measured intensities and for signal refencing, thereby accounting for excitation light-induced intensity fluctuations. Moreover, there is an ever increasing need for fluorescence quantum yield standards with well known and preferably certified quantum yields. Moreover, although already challenging for the UV/vis/NIR spectral region, there is an increasing interest particularly by the fluorescence imaging community to expand the waveelngth region applied from the NIR to measurements > 1000 nm. Presently, there are no fluorescence standards for this wavelength region available, rendering the control of instrument calibration in this wavelength region basically impossible. In this respect, we present reliable and validated procedures for the calibration of fluorescence measuring devices from 300 nm to 1700 nm using different types of physical and chemical standards. Moreover, a new set of fluorescence quantum yield standards covering the UV/vis/NIR is been introduced that is currently under certification at BAM.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Resch-Genger_Methods for the calibration of fluorescene setups.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Ute Resch-GengerORCiD
Koautor*innen:Ute Resch-Genger, Christian Würth, Katrin Hoffmann, Arne Güttler, Martin Kaiser, Soheil Hatami, Ute Resch-Genger
Dokumenttyp:Vortrag
Veröffentlichungsform:Präsentation
Sprache:Englisch
Jahr der Erstveröffentlichung:2016
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurwissenschaften und zugeordnete Tätigkeiten
Freie Schlagwörter:biotechnological; pharmaceutical
Veranstaltung:Arbeitskreis, Mass Spectrometry Facility
Veranstaltungsort:University of Berkeley, CA, USA
Beginndatum der Veranstaltung:13.02.2016
Enddatum der Veranstaltung:13.02.2016
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:15.06.2016
Referierte Publikation:Nein
Eingeladener Vortrag:Nein
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.