Gravimetric preparation and characterization of a primary reference solution of molybdenum

  • Gravimetrically prepared mono-elemental reference solutions having a well-known mass fraction of approximately 1 g/kg define the very basis of virtually all measurements in inorganic analysis. Serving as the starting materials of all standard/calibration solutions, they link virtually all measurements of inorganic analytes to the purity of the solid materials they were prepared from. In case these solid materials are characterized comprehensively with respect to their purity, this link also establishes direct metrological traceability to The International System of Unit. Within the framework of the European Metrology Research Programme (EMRP), in the Joint Research Project called SIB09 Primary standards for challenging elements, a reference solution of molybdenum was prepared directly from the respective metal with a relative expanded uncertainty associated with the mass fraction of Urel(w) < 0.05 %. A highly accurate and precise ICP OES and MC-ICP-MS method was developed to assistGravimetrically prepared mono-elemental reference solutions having a well-known mass fraction of approximately 1 g/kg define the very basis of virtually all measurements in inorganic analysis. Serving as the starting materials of all standard/calibration solutions, they link virtually all measurements of inorganic analytes to the purity of the solid materials they were prepared from. In case these solid materials are characterized comprehensively with respect to their purity, this link also establishes direct metrological traceability to The International System of Unit. Within the framework of the European Metrology Research Programme (EMRP), in the Joint Research Project called SIB09 Primary standards for challenging elements, a reference solution of molybdenum was prepared directly from the respective metal with a relative expanded uncertainty associated with the mass fraction of Urel(w) < 0.05 %. A highly accurate and precise ICP OES and MC-ICP-MS method was developed to assist with the preparation and as a dissemination tool.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • SRichter_2015-ANAKON.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:J. Noordmann
Koautor*innen:Silke Richter, Heinrich Kipphardt, A. Kaltenbach, V. Görlitz, O. Rienitz
Dokumenttyp:Posterpräsentation
Veröffentlichungsform:Präsentation
Sprache:Englisch
Jahr der Erstveröffentlichung:2015
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Freie Schlagwörter:Metrology; Mo; Primary standards
Veranstaltung:ANACON
Veranstaltungsort:Graz, Austria
Beginndatum der Veranstaltung:23.03.2015
Enddatum der Veranstaltung:26.03.2015
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:30.03.2017
Referierte Publikation:Nein
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.