Cr, Cu and Zn K-edge SR-TXRF-XANES of indoor aerosol samples at BESSY II and ELETTRA
- Airborne particulate matter is an issue of growing concern in industrialized countries. Particles with diameters of less than 10 μm (especially those smaller than 2.5 μm) can enter the human respiratory system and contribute to various diseases depending on their chemical composition and the chemical bonding state, in which elements are present. This chemical speciation can be obtained using X-ray absorption near-edge structure analysis (XANES), which requires a tunable excitation source and therefore has to be carried out at synchrotron facilities. Our special interest lies on the analysis of indoor airborne particulate matter, as particle composition and health effects of outdoor particles have been studied abundantly. For this work, samples were collected in various office rooms in the Atominstitut (ATI) building. The BAMline at BESSYII features a double-multilayer monochromator (DMM) and a double-crystal monochromator (DCM). The DCM offers an energy resolution E/ΔE of around 103,Airborne particulate matter is an issue of growing concern in industrialized countries. Particles with diameters of less than 10 μm (especially those smaller than 2.5 μm) can enter the human respiratory system and contribute to various diseases depending on their chemical composition and the chemical bonding state, in which elements are present. This chemical speciation can be obtained using X-ray absorption near-edge structure analysis (XANES), which requires a tunable excitation source and therefore has to be carried out at synchrotron facilities. Our special interest lies on the analysis of indoor airborne particulate matter, as particle composition and health effects of outdoor particles have been studied abundantly. For this work, samples were collected in various office rooms in the Atominstitut (ATI) building. The BAMline at BESSYII features a double-multilayer monochromator (DMM) and a double-crystal monochromator (DCM). The DCM offers an energy resolution E/ΔE of around 103, which makes it suitable for XANES applications. The ATI SR-TXRF vacuum chamber, formerly located at HASYLAB, Beamline L, is now available at the BAMline. The chamber offers a sample changer for up to 8 quartz reflectors and a 30 mm² silicon drift detector (SDD) was used. Aerosol samples were produced using a modified three-stage Dekati™ impactor. For this work, only the coarse (2.5 to 10 μm) and the fine particle fraction (1 to 2.5 μm), were of interest. XANES results of Cr, Cu and Zn will be presented on this poster. The X-ray Fluorescence beamline at ELETTRA operates in partnership with the IAEA an ultra-high vacuum instrument with a 7-axis manipulator suitable for a variety of X-ray analytical techniques, such as grazing incidence and total reflection X-ray fluorescence analysis (GI-XRF and TXRF), X-ray reflectometry (XRR) and XANES. Samples were produced using a four-stage Sioutas Personal Cascade Impactor. With this impactor, it is possible to produce size-fractionated samples down to the sub-μm range (Stages: A > 2.5 μm, B 1 to 2.5 μm, C 0.5 to 1 μm and D 0.25 to 0.5 μm). Direct sampling was performed on siliconized 25 mm Si wafers suitable for TXRF. Cu-K edge SR-TXRF-XANES analysis was carried out for samples of all impactor stages. Results of these experiments will be shown.…
Autor*innen: | J. Prost |
---|---|
Koautor*innen: | A. Windbichler, Ana de Oliveira Guilherme BuzanichORCiD, Uwe Reinholz, Heinrich Riesemeier, Martin RadtkeORCiD, G. Pepponi, A. Migliori, A.G. Karydas, M. Czyzycki, D.M. Eichert, W.H. Jark, P. Wobrauschek, C. Streli |
Dokumenttyp: | Posterpräsentation |
Veröffentlichungsform: | Präsentation |
Sprache: | Englisch |
Jahr der Erstveröffentlichung: | 2016 |
DDC-Klassifikation: | Naturwissenschaften und Mathematik / Chemie / Analytische Chemie |
Freie Schlagwörter: | Aerosol; BAMline; BESSY; Synchrotron; XANES |
Veranstaltung: | European Conference on X-Ray Spectrometry (EXRS) |
Veranstaltungsort: | Gothenburg, Sweden |
Beginndatum der Veranstaltung: | 19.06.2016 |
Enddatum der Veranstaltung: | 24.06.2016 |
Verfügbarkeit des Dokuments: | Datei im Netzwerk der BAM verfügbar ("Closed Access") |
Datum der Freischaltung: | 21.12.2016 |
Referierte Publikation: | Nein |