• Treffer 11 von 138
Zurück zur Trefferliste

GPR Dataset of Moisture Measurements on Building Floors in Laboratory and On-Site

  • Related work Laboratory Study: Combining Signal Features of Ground-Penetrating Radar to Classify Moisture Damage in Layered Building Floors https://doi.org/10.3390/app11198820 On-Site Study: TBA Doctoral Thesis: Non-destructive classification of moisture deterioration in layered building floors using ground penetrating radar https://doi.org/10.14279/depositonce-19306 Measurement Parameters The GPR measurements were carried out with the SIR 20 from GSSI and a 2 GHz antenna pair (bandwidth 1 GHz to 3 GHz) in common-offset configuration. Each B-Scan consists of N A-Scans, each including 512 samples of a 11 ns time window. Survey lines were recorded with 250 A-Scans/ meter, which equals a 4 mm spacing between each A-Scan No Gains were applied. Folder Description: Lab_dry, Lab_insulDamage, Lab_screedDamage - each contain 168 Measurements (B-Scans) in .csv on 84 dry floors, floors with insulation damage and screed damage. - each floor setup was measured twice onRelated work Laboratory Study: Combining Signal Features of Ground-Penetrating Radar to Classify Moisture Damage in Layered Building Floors https://doi.org/10.3390/app11198820 On-Site Study: TBA Doctoral Thesis: Non-destructive classification of moisture deterioration in layered building floors using ground penetrating radar https://doi.org/10.14279/depositonce-19306 Measurement Parameters The GPR measurements were carried out with the SIR 20 from GSSI and a 2 GHz antenna pair (bandwidth 1 GHz to 3 GHz) in common-offset configuration. Each B-Scan consists of N A-Scans, each including 512 samples of a 11 ns time window. Survey lines were recorded with 250 A-Scans/ meter, which equals a 4 mm spacing between each A-Scan No Gains were applied. Folder Description: Lab_dry, Lab_insulDamage, Lab_screedDamage - each contain 168 Measurements (B-Scans) in .csv on 84 dry floors, floors with insulation damage and screed damage. - each floor setup was measured twice on two orthogonal survey lines, indicated by _Line1_ and _Line2_ in the file name. - the file names encode the building floor setup e.g. CT50XP100 describes a 50 mm cement screed with 100 mm extruded polystyrene below - the material codes are CT: cement screed, CA: anhydrite screed, EP: expanded polystyrene, XP: extruded polystyrene, GW: glass wool, PS: perlites further information can be found in the publication https://doi.org/10.3390/app11198820 OnSite_ - 5 folders containing B-Scans on 5 different practical moisture damages - the building floor setup is encoded according to the lab with an additional measurement point numbering at the start and a damage case annotation at the end of the file name with _dry, _insulationDamage and_screedDamage File Description: B-Scans, Measurement files - no header - dimension: 512 x N data point with N beeing the number of A-Scans including 512 samples of a 11 ns time window. - survey lines were recorded with 250 A-Scans/ meter, which equals a 4 mm spacing between each A-Scan Moisture References - Moist_Reference of On-Site Locations include the columns MeasPoint: Measurement point, wt%Screed: moisture content of screed layer in mass percent; wt%Insul: moisture content of insulation layer in mass percent. References were obtained by drilling cores with 68 mm diameter in the center of each survey line. - Moist_Reference_Screed of Lab data include the columns Screed: Screed material and thickness in mm, wt%Screed moisture content of screed layer in mass percent - Moist Reference_Insul of Lab data include the columns Insulation: Insulation material and thickness in mm, water addition in l: water added to the insulation layer in liters, V%Insulation: water added to the insulation layer in volume percent, RH%: resulting relative humidy in the insulation layer during measurement. These References are only avaible for Lab measurements on insulation damages.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Tim Klewe, Christoph Strangfeld, Tobias Ritzer, Sabine Kruschwitz
Dokumenttyp:Forschungsdatensatz
Veröffentlichungsform:Graue Literatur
Sprache:Englisch
Jahr der Erstveröffentlichung:2024
Organisationseinheit der BAM:8 Zerstörungsfreie Prüfung
8 Zerstörungsfreie Prüfung / 8.0 Abteilungsleitung und andere
Herausgeber (Institution):Bundesanstalt für Materialforschung und -prüfung (BAM)
Verlag:Zenodo
Verlagsort:Geneva
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Sanitär- und Kommunaltechnik; Umwelttechnik
Freie Schlagwörter:Building Floors; GPR; Laboratory; Material Moisture; On-Site
Themenfelder/Aktivitätsfelder der BAM:Umwelt
Umwelt / Sensorik
Art der Ressource:Datensatz
DOI:10.5281/zenodo.10776684
Zugehöriger Identifikator:https://nbn-resolving.org/urn:nbn:de:kobv:b43-533606
Verfügbarkeit des Dokuments:Datei für die Öffentlichkeit verfügbar ("Open Access")
Lizenz (Deutsch):License LogoCreative Commons - CC BY - Namensnennung 4.0 International
Datum der Freischaltung:14.03.2024
Referierte Publikation:Nein
Schriftenreihen ohne Nummerierung:Forschungsdatensätze der BAM
Einverstanden