Evaluation of radiographic testing performance with an advanced POD approach

  • POD is the most often used approach for the evaluation of the reliability of non-destructive testing methods in critical areas. But especially for those cases the requirements for a sufficient amount of data, adequate type of defects and the statistical requirements are high. The claim for checking these requirements is not new, but never the less often ignored. Especially the large amount of data for critical real defects seems too often to be not really solvable. In this presentation we show an approach to use real defect data with knowledge from former testing results with the same equipment, in a useful adequate way. Furthermore we introduce a method to evaluate the real defect description parameters for the radiographic testing. This approach was used for a joint project with the company POSIVA, which is building a final depository for spent nuclear fuel in Finland. Radiographic testing is one of the NDT-methods they use to test the electron beam weld of the copper canister. ThePOD is the most often used approach for the evaluation of the reliability of non-destructive testing methods in critical areas. But especially for those cases the requirements for a sufficient amount of data, adequate type of defects and the statistical requirements are high. The claim for checking these requirements is not new, but never the less often ignored. Especially the large amount of data for critical real defects seems too often to be not really solvable. In this presentation we show an approach to use real defect data with knowledge from former testing results with the same equipment, in a useful adequate way. Furthermore we introduce a method to evaluate the real defect description parameters for the radiographic testing. This approach was used for a joint project with the company POSIVA, which is building a final depository for spent nuclear fuel in Finland. Radiographic testing is one of the NDT-methods they use to test the electron beam weld of the copper canister. The copper canister will be used in the deposit as a corrosion barrier within the deposit concept. Through the high sophisticated manufacturing methods of the canister there are almost no material defects, which could be used for reliability evaluation. In this context the idea of Bayesian Updating of the POD with real defect data with former results from artificial defect data was born to get a useful evaluation.zeige mehrzeige weniger

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Daniel Kanzler, Christina Müller, J. Pitkänen
Dokumenttyp:Beitrag zu einem Tagungsband
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):5th European-American workshop on reliability of NDE
Jahr der Erstveröffentlichung:2013
Veröffentlichende Institution:Bundesanstalt für Materialforschung und -prüfung (BAM)
Verlag:Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP)
Verlagsort:Berlin
Ausgabe/Heft:DGZfP-BB 144
Erste Seite:Lecture 4, 1
Letzte Seite:7
Veranstaltung:5th European-American workshop on reliability of NDE
Veranstaltungsort:Berlin, Germany
Beginndatum der Veranstaltung:07.10.2013
Enddatum der Veranstaltung:10.10.2013
URN:urn:nbn:de:kobv:b43-312641
ISBN:978-3-940283-53-5
Verfügbarkeit des Dokuments:Datei für die Öffentlichkeit verfügbar ("Open Access")
Lizenz (Deutsch):License LogoCreative Commons - Namensnennung
Datum der Freischaltung:31.12.2015
Referierte Publikation:Nein
Schriftenreihen ohne Nummerierung:Wissenschaftliche Artikel der BAM
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.