Validation of a fast and traceable radiographic scale calibration of dimensional computed tomography
- A fast and highly precise method of determining the geometrical scale factor of computed tomography (CT) measurements has been validated successfully by Bundesanstalt für Materialforschung und -prüfung (BAM), the Federal Institute of Metrology (METAS) and Physikalisch-Technische Bundesanstalt (PTB) within the scope of AdvanCT (Advanced Computed Tomography for dimensional and surface measurements in industry), a project funded in the European Metrology Programme for Innovation and Research (EMPIR). The method has been developed by PTB and requires only two radiographic images of a calibrated thin 2D standard (hole grid standard) from two opposite directions. The mean grid distance is determined from both radiographs. From this and with the help of the calibration result, the radiographic scale and therefore the voxel size is determined. The procedure takes only a few minutes and avoids a time-consuming CT scan. To validate the method, the voxel sizes determined via this method wereA fast and highly precise method of determining the geometrical scale factor of computed tomography (CT) measurements has been validated successfully by Bundesanstalt für Materialforschung und -prüfung (BAM), the Federal Institute of Metrology (METAS) and Physikalisch-Technische Bundesanstalt (PTB) within the scope of AdvanCT (Advanced Computed Tomography for dimensional and surface measurements in industry), a project funded in the European Metrology Programme for Innovation and Research (EMPIR). The method has been developed by PTB and requires only two radiographic images of a calibrated thin 2D standard (hole grid standard) from two opposite directions. The mean grid distance is determined from both radiographs. From this and with the help of the calibration result, the radiographic scale and therefore the voxel size is determined. The procedure takes only a few minutes and avoids a time-consuming CT scan. To validate the method, the voxel sizes determined via this method were compared with voxel sizes determined from CT scans of calibrated objects. Relative deviations between the voxel sizes in the range of 10−5 were achieved with minimal effort using cone-beam CT systems at moderate magnifications.…
Autor*innen: | U. Neuschaefer-RubeORCiD, J. Illemann, M. Sturm, B. BircherORCiD, F. MeliORCiD, Carsten BellonORCiD, Sergei EvsevleevORCiD |
---|---|
Dokumenttyp: | Zeitschriftenartikel |
Veröffentlichungsform: | Verlagsliteratur |
Sprache: | Englisch |
Titel des übergeordneten Werkes (Englisch): | Measurement Science and Technology |
Jahr der Erstveröffentlichung: | 2022 |
Organisationseinheit der BAM: | 8 Zerstörungsfreie Prüfung |
8 Zerstörungsfreie Prüfung / 8.5 Röntgenbildgebung | |
Veröffentlichende Institution: | Bundesanstalt für Materialforschung und -prüfung (BAM) |
Verlag: | IOP Publishing |
Verlagsort: | Bristol, UK |
Jahrgang/Band: | 33 |
Ausgabe/Heft: | 9 |
Aufsatznummer: | 094007 |
Erste Seite: | 1 |
Letzte Seite: | 9 |
DDC-Klassifikation: | Naturwissenschaften und Mathematik / Chemie / Analytische Chemie |
Freie Schlagwörter: | Dimensional metrology; Geometrical magnification; Industrial CT; Voxel size |
Themenfelder/Aktivitätsfelder der BAM: | Chemie und Prozesstechnik |
DOI: | 10.1088/1361-6501/ac74a3 |
URN: | urn:nbn:de:kobv:b43-553271 |
ISSN: | 0957-0233 |
Verfügbarkeit des Dokuments: | Datei für die Öffentlichkeit verfügbar ("Open Access") |
Lizenz (Deutsch): | Creative Commons - CC BY - Namensnennung 4.0 International |
Datum der Freischaltung: | 21.07.2022 |
Referierte Publikation: | Ja |
Datum der Eintragung als referierte Publikation: | 21.07.2022 |
Schriftenreihen ohne Nummerierung: | Wissenschaftliche Artikel der BAM |