Zitieren Sie bitte immer diesen URN: urn:nbn:de:kobv:b43-542346
A rapid magnetic bead-based immunoassay for sensitive determination of diclofenac
- Increasing contamination of environmental waters with pharmaceuticals represents an emerging threat for the drinking water quality and safety. In this regard, fast and reliable analytical methods are required to allow quick countermeasures in case of contamination. Here, we report the development of a magnetic bead-based immunoassay (MBBA) for the fast and cost-effective determination of the analgesic diclofenac (DCF) in water samples, based on diclofenac-coupled magnetic beads and a robust monoclonal anti-DCF antibody. A novel synthetic strategy for preparation of the beads resulted in an assay that enabled for the determination of diclofenac with a significantly lower limit of detection (400 ng/L) than the respective enzyme-linked immunosorbent assay (ELISA). With shorter incubation times and only one manual washing step required, the assay demands for remarkably shorter time to result (< 45 min) and less equipment than ELISA. Evaluation of assay precision and accuracy with a seriesIncreasing contamination of environmental waters with pharmaceuticals represents an emerging threat for the drinking water quality and safety. In this regard, fast and reliable analytical methods are required to allow quick countermeasures in case of contamination. Here, we report the development of a magnetic bead-based immunoassay (MBBA) for the fast and cost-effective determination of the analgesic diclofenac (DCF) in water samples, based on diclofenac-coupled magnetic beads and a robust monoclonal anti-DCF antibody. A novel synthetic strategy for preparation of the beads resulted in an assay that enabled for the determination of diclofenac with a significantly lower limit of detection (400 ng/L) than the respective enzyme-linked immunosorbent assay (ELISA). With shorter incubation times and only one manual washing step required, the assay demands for remarkably shorter time to result (< 45 min) and less equipment than ELISA. Evaluation of assay precision and accuracy with a series of spiked water samples yielded results with low to moderate intra- and inter-assay variations and in good agreement with LC–MS/MS reference analysis. The assay principle can be transferred to other, e.g., microfluidic, formats, as well as applied to other analytes and may replace ELISA as the standard immunochemical method.…
Autor*innen: | Alexander EckeORCiD, Tanja Westphalen, J. Hornung, M. Voetz, Rudolf SchneiderORCiD |
---|---|
Dokumenttyp: | Zeitschriftenartikel |
Veröffentlichungsform: | Verlagsliteratur |
Sprache: | Englisch |
Titel des übergeordneten Werkes (Englisch): | Analytical and Bioanalytical Chemistry |
Jahr der Erstveröffentlichung: | 2021 |
Organisationseinheit der BAM: | 1 Analytische Chemie; Referenzmaterialien |
1 Analytische Chemie; Referenzmaterialien / 1.8 Umweltanalytik | |
Veröffentlichende Institution: | Bundesanstalt für Materialforschung und -prüfung (BAM) |
Verlag: | Springer |
Verlagsort: | Heidelberg |
Jahrgang/Band: | 414 |
Erste Seite: | 1563 |
Letzte Seite: | 1573 |
DDC-Klassifikation: | Naturwissenschaften und Mathematik / Chemie / Analytische Chemie |
Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Sanitär- und Kommunaltechnik; Umwelttechnik | |
Freie Schlagwörter: | Diclofenac; Immunoassay; LC-MS/MS; Magnetic beads; Water analysis |
Themenfelder/Aktivitätsfelder der BAM: | Chemie und Prozesstechnik |
Chemie und Prozesstechnik / Chemische Charakterisierung und Spurenanalytik | |
Umwelt | |
DOI: | 10.1007/s00216-021-03778-7 |
URN: | urn:nbn:de:kobv:b43-542346 |
ISSN: | 1618-2650 |
Verfügbarkeit des Dokuments: | Datei für die Öffentlichkeit verfügbar ("Open Access") |
Lizenz (Deutsch): | Creative Commons - CC BY - Namensnennung 4.0 International |
Datum der Freischaltung: | 24.01.2022 |
Referierte Publikation: | Ja |
Datum der Eintragung als referierte Publikation: | 24.01.2022 |
Schriftenreihen ohne Nummerierung: | Wissenschaftliche Artikel der BAM |