Influence of the real energy input on the sensitivity of thermographic testing in case of GFRP

  • Thermographic testing (TT) is an upcoming nondestructive method, which requires no contact at all to the specimen and can be applied on larger areas simultaneously. The measurement concept is based on the production of a thermal imbalance at the surface of the object under test. When the surface of this object is heated by an external source for a certain time, the surface temperature drops subsequently, influenced by inner defects of the sample. This leads to thermal contrasts at the surface. It is crucial that those contrasts are large enough to be detectable above the noise level. In a first approximation, the observed temperature contrast at a defect is proportional to the energy which was really introduced into the specimen during the heating period. However, the real energy input in a TT experiment is almost always unknown due to distinct parameters of the experimental setup or the material investigated. Typically, only the power consumption of the heating sources is reported,Thermographic testing (TT) is an upcoming nondestructive method, which requires no contact at all to the specimen and can be applied on larger areas simultaneously. The measurement concept is based on the production of a thermal imbalance at the surface of the object under test. When the surface of this object is heated by an external source for a certain time, the surface temperature drops subsequently, influenced by inner defects of the sample. This leads to thermal contrasts at the surface. It is crucial that those contrasts are large enough to be detectable above the noise level. In a first approximation, the observed temperature contrast at a defect is proportional to the energy which was really introduced into the specimen during the heating period. However, the real energy input in a TT experiment is almost always unknown due to distinct parameters of the experimental setup or the material investigated. Typically, only the power consumption of the heating sources is reported, sometimes combined with the distance to the specimen surface. This contribution describes the thermographic inspection of a rear side thickness variation from 1 to 2 cm at GFRP. This could represent a rear side adhesive bond i.e. in a wind turbine rotor blade. The front side heating was realized by usual halogen lamps with variable radiation power. The detected temperature contrast at the front side will be related to the different energy inputs determined by means of a simple analytical model applied to the experimental data. Additionally, the experimental data are compared with results of FEM simulations performed by COMSOL Multiphysics. The results clearly demonstrate the key role of the real energy input in a real TT setup, if detection limits have to be evaluated.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • 2018-06_ECNDT_Vortrag_Mueller_final.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Jan P. Müller
Koautor*innen:Rainer Krankenhagen
Dokumenttyp:Vortrag
Veröffentlichungsform:Präsentation
Sprache:Englisch
Jahr der Erstveröffentlichung:2018
Organisationseinheit der BAM:8 Zerstörungsfreie Prüfung
8 Zerstörungsfreie Prüfung / 8.0 Abteilungsleitung und andere
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurwissenschaften und zugeordnete Tätigkeiten
Freie Schlagwörter:Energieeintrag; GFK; Rotorblatt; Thermografie mit Stufenanregung; Zerstörungsfreie Prüfung
Themenfelder/Aktivitätsfelder der BAM:Material
Material / Degradation von Werkstoffen
Veranstaltung:ECNDT 2018
Veranstaltungsort:Göteborg, Sweden
Beginndatum der Veranstaltung:11.06.2018
Enddatum der Veranstaltung:15.06.2018
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:04.07.2018
Referierte Publikation:Nein
Eingeladener Vortrag:Nein
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.