Finite Element Model Calibration of a Historic Wiegmann–Polonceau Truss Based on Experimental Modal Parameters

  • This paper describes the experimental calibration of an existing Wiegmann–Polonceau roof truss based on modal parameters. Dynamic tests allowed the determination of the natural frequencies and mode shapes of the global truss and of individual truss members. The global and local modal configurations as well as coupled vibration of truss members are discussed. In addition, as truss members are axially loaded, the effect of stress stiffening on the modal parameters is considered. Moreover, several finite element models with different modelling assumptions for the details of the connections and member geometrical characteristics such as gusset plates and turnbuckles were developed. A suitable numerical model was chosen to represent the truss structural behavior. This paper focuses on the local measurement and analysis strategies applied to single truss members. The possibility of using a local analysis method, namely methods that consider individual members as part of a structure, isThis paper describes the experimental calibration of an existing Wiegmann–Polonceau roof truss based on modal parameters. Dynamic tests allowed the determination of the natural frequencies and mode shapes of the global truss and of individual truss members. The global and local modal configurations as well as coupled vibration of truss members are discussed. In addition, as truss members are axially loaded, the effect of stress stiffening on the modal parameters is considered. Moreover, several finite element models with different modelling assumptions for the details of the connections and member geometrical characteristics such as gusset plates and turnbuckles were developed. A suitable numerical model was chosen to represent the truss structural behavior. This paper focuses on the local measurement and analysis strategies applied to single truss members. The possibility of using a local analysis method, namely methods that consider individual members as part of a structure, is demonstrated to assess the behavior of the global truss structure. The comparison of the results after calibration reveals a very good correlation between the experimentally identified and numerically estimated modal parameters of the historic truss.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Luong et al_Springer_LNCE5_EVACES2017.pdf
    eng
  • Buch__Inhaltsverzeichnis.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Thi Mai Hoa Luong, W. Lorenz, R.G. Rohrmann, V. Zabel, Samir Said
Persönliche Herausgeber*innen: Springer, Cham
Dokumenttyp:Buchkapitel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Experimental Vibration Analysis for Civil Structures: Testing, Sensing, Monitoring, and Control
Auflage:1
Jahr der Erstveröffentlichung:2017
Verlag:Springer International Publishing
Jahrgang/Band:5
Erste Seite:212
Letzte Seite:224
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurbau
Freie Schlagwörter:Axial force; Dynamic test; Finite element method; Modal parameters; Truss structures
DOI:10.1007/978-3-319-67443-8_18
ISSN:2366-2557
ISBN:978-3-319-67443-8
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:24.10.2017
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:24.01.2019
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.