Improved 3D-imaging of a sirolimus/probucol eluting stent coating using laser postionization secondary neutral mass spectrometry and time-of-flight secondary ion mass spectrometry

  • Implantable drug delivery systems that provide controlled and sustained release of a therapeutic agent are used in a wide variety of applications. Drug eluting stents, which are used to treat coronary artery disease, are among the most widespread of these devices, with an estimated 3x10⁶ implants annually worldwide. Controlling the rate of drug release from these devices relies on precise control of the three dimensional (3D)-distribution of the drug, so methods for measuring this distribution are of great importance. The aims of this work were to determine how 3D-imaging of polymer-free sirolimus/probucol drug eluting stent coatings could be improved through the use of laser postionization secondary neutral mass spectrometry (Laser- SNMS) and Ar cluster sputtering with time-of-flight secondary ion mass spectrometry (ToF-SIMS) and to optimize conditions for this analysis. In this study, 3D-imaging of a sirolimus/probucol dual drug eluting stent has been investigated using Laser-SNMSImplantable drug delivery systems that provide controlled and sustained release of a therapeutic agent are used in a wide variety of applications. Drug eluting stents, which are used to treat coronary artery disease, are among the most widespread of these devices, with an estimated 3x10⁶ implants annually worldwide. Controlling the rate of drug release from these devices relies on precise control of the three dimensional (3D)-distribution of the drug, so methods for measuring this distribution are of great importance. The aims of this work were to determine how 3D-imaging of polymer-free sirolimus/probucol drug eluting stent coatings could be improved through the use of laser postionization secondary neutral mass spectrometry (Laser- SNMS) and Ar cluster sputtering with time-of-flight secondary ion mass spectrometry (ToF-SIMS) and to optimize conditions for this analysis. In this study, 3D-imaging of a sirolimus/probucol dual drug eluting stent has been investigated using Laser-SNMS and ToF-SIMS. Laser-SNMS studies of pure sirolimus and probucol were undertaken using 30 keV Bi₃⁺ primary Ions and a 157 nm excimer postionization laser. Under optimal conditions, a greater than 100-fold increase in detected ion yield was observed for Laser-SNMS when compared to ToF-SIMS, although ToF-SIMS provided equal or greater yields for higher mass characteristic ions. Although the optimal laser power density for detecting probucol (5x10⁶W/cm²) was significantly lower than the optimum for sirolimus(7x10⁷W/cm²), an intermediate laser power density of 1x10⁷W/cm² was sufficient to allow imaging of both drugs. Using individual selected ion signals, ToF-SIMS and Laser-SNMS produced similar images of the two drug species. When using, however, a multivariate approach (Maximum autocorrelation factors), Laser-SNMS provided significant improvements in image contrast and small area detection when compared to ToF-SIMS. Following optimization of the technique, 3D-images of the dual drug eluting stent coating were obtained using 10 keV Ar₂₀₀₀⁺ cluster ions for sputtering and 30 keV Bi₃⁺ cluster ions for Analysis for both ToF-SIMS and Laser-SNMS. This work demonstrates the advantages of Laser-SNMS for 3D-imaging of pharmaceutical devices, which has not been previously published. Both ToF-SIMS and Laser-SNMS revealed that the outermost surface of the drug eluting coating contained pure sirolimus to a depth of a few tens of nanometers, with a few channels of sirolimus extending to a depth of around 1 lm. Below about 1 lm, the two drugs were uniformly mixed. Using the 10 keV Ar₂₀₀₀⁺ sputter beam, the authors were able to sputter through the complete drug coating (~6 μm) without observing any accumulated damage in the organic layer. The two techniques showed complementary strengths: ToF-SIMS offers faster data collection and better detected ion yield for larger characteristic ions than Laser-SNMS, and Laser-SNMS offers significantly enhanced detected ion yield for smaller fragment ions, allowing for improved Image contrast and Resolution of smaller features.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Pelster2016_Biointerphases.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Wolfgang UngerORCiD, A. Pelster, B.J. Tyler, M. Kösgen, R. Kassenböhmer, R.E. Peterson, M. Stöver, H. F. Arlinghaus
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Biointerphases
Jahr der Erstveröffentlichung:2016
Herausgeber (Institution):AVS: Science & Technology of Materials, Interfaces, and Processing
Verlag:AVS: Science & Technology of Materials, Interfaces, and Processing
Jahrgang/Band:11
Ausgabe/Heft:4
Erste Seite:041001-1
Letzte Seite:041001-10
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Freie Schlagwörter:Eluting stent; Imaging ToF SIMS
DOI:10.1116/1.4964687
ISSN:1934-8630
ISSN:1559-4106
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:16.11.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:23.02.2017
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.