Method-verification and optimisation of the standardised assessment of odour intensity regarding ISO 16000-28
- Besides measurement of VOC emissions also the evaluation of odour emissions and the perceived intensity of odours gains in importance. Due to difficulties detected in the measurement method of the perceived intensity described in (ISO 16000-28, 2012) the introduction of “reference” odours will be recommended for the training of panellists and as basis for interlaboratory comparisons. In order to generate the “reference” odours standard liquid substances were directly injected into the main gas flow provided to the panellists. One of the substances tested was ethyl acetate. A pre-evaluation was conducted with six untrained panellists and has shown that ethyl acetate is potentially suitable as reference odour. For further validation of those “reference” odours they additionally will be provided to and evaluated by trained panellists of well established-measurement institutes.
Autor*innen: | Laura Brosig, Wolfgang HornORCiD, Oliver Jann |
---|---|
Dokumenttyp: | Beitrag zu einem Tagungsband |
Veröffentlichungsform: | Graue Literatur |
Sprache: | Englisch |
Titel des übergeordneten Werkes (Englisch): | Proceedings Indoor Air Conference 2016 |
Jahr der Erstveröffentlichung: | 2016 |
Erste Seite: | Paper 568, 1 |
Letzte Seite: | 6 |
DDC-Klassifikation: | Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurwissenschaften und zugeordnete Tätigkeiten |
Freie Schlagwörter: | Building products; Emission testing; Odour assessment; Perceived odour intensity; Reference odour |
Veranstaltung: | Indoor Air 2016 The 14th international conference of Indoor Air Quality and Climate |
Veranstaltungsort: | Ghent, Belgium |
Beginndatum der Veranstaltung: | 03.07.2016 |
Enddatum der Veranstaltung: | 08.07.2016 |
ISBN: | 978-0-9846855-5-4 |
Verfügbarkeit des Dokuments: | Datei im Netzwerk der BAM verfügbar ("Closed Access") |
Datum der Freischaltung: | 24.11.2016 |
Referierte Publikation: | Nein |