Application of spatial heterodyne spectroscopy for chemical analysis based on Raman and laser-induced breakdown spectroscopy

  • Spatial Heterodyne Spectroscopy (SHS) is a spectrometric technique that combines both dispersive and interferometric features into a customizable instrument. The Basis of SHS is a Michelson interferometer with its mirrors replaced by diffraction gratings and with no moving parts. The output signal from SHS is the interferogram, which is recorded with a 1D or 2D pixel array detector. The spatial periodicity of the fringes on the interferogram is a function of the wavelength of the diffracted light. Using the Fast Fourier Transform, the original optical spectrum that enters SHS is retrieved. The light that is analyzed by SHS can come from a variety of sources. In our work, we used Raman scattering and Laser-Induced Plasma to perform quantitative and qualitative analyses. Figure 1 compares the performance of the SHS with that of high Resolution echelle and portable low-resolution asymmetrically crossed Czerny-Turner spectrometers (OO in Fig.1). The analyzed light came from the plasmaSpatial Heterodyne Spectroscopy (SHS) is a spectrometric technique that combines both dispersive and interferometric features into a customizable instrument. The Basis of SHS is a Michelson interferometer with its mirrors replaced by diffraction gratings and with no moving parts. The output signal from SHS is the interferogram, which is recorded with a 1D or 2D pixel array detector. The spatial periodicity of the fringes on the interferogram is a function of the wavelength of the diffracted light. Using the Fast Fourier Transform, the original optical spectrum that enters SHS is retrieved. The light that is analyzed by SHS can come from a variety of sources. In our work, we used Raman scattering and Laser-Induced Plasma to perform quantitative and qualitative analyses. Figure 1 compares the performance of the SHS with that of high Resolution echelle and portable low-resolution asymmetrically crossed Czerny-Turner spectrometers (OO in Fig.1). The analyzed light came from the plasma induced on a stainless-steel reference material. The SHS exhibits the resolution comparable to that of the echelle spectrometer used, about 8000. Due to a high throughput of the SHS (theoretically, ~200 times higher than that of grating instruments), the number of spectra needed to be accumulated for comparable signal-to-noise ratios is much smaller than in the case of the echelle and comparable to OO spectrometers. Examples of Raman SHS applied to several pure liquids are given in Fig. 2. Raman SHS was used in three different settings: (i) for classification of six types of oils, (ii) for univariate/multivariate analysis of binary mixture cyclohexane-isopropanol, and (iii) for multivariate analysis of glycerol solution in water. For the last two settings, chemometric analysis of the spectra yielded linear calibration plots over the range 1-90% of concentrations of isopropanol in cyclohexane, and 0.5-10% of glycerol in water.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • 190326_ANAKON_Gojani.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Ardian GojaniORCiD
Koautor*innen:David J. Palásti, Andrea Paul, G. Galbacs, Igor B. Gornushkin
Dokumenttyp:Vortrag
Veröffentlichungsform:Präsentation
Sprache:Englisch
Jahr der Erstveröffentlichung:2019
Organisationseinheit der BAM:1 Analytische Chemie; Referenzmaterialien
1 Analytische Chemie; Referenzmaterialien / 1.4 Prozessanalytik
1 Analytische Chemie; Referenzmaterialien / 1.9 Chemische und optische Sensorik
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Freie Schlagwörter:Laser-Induced Background Spectroscopy; Raman spectroscopy; Spatial heterodyne spectroscopy
Themenfelder/Aktivitätsfelder der BAM:Chemie und Prozesstechnik
Veranstaltung:ANAKON 2019
Veranstaltungsort:Münster, Germany
Beginndatum der Veranstaltung:25.03.2019
Enddatum der Veranstaltung:25.03.2019
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:01.10.2019
Referierte Publikation:Nein
Eingeladener Vortrag:Nein
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.