Das Suchergebnis hat sich seit Ihrer Suchanfrage verändert. Eventuell werden Dokumente in anderer Reihenfolge angezeigt.
  • Treffer 6 von 321
Zurück zur Trefferliste

Metal based pollutant assessment via diatoms - new possibilities via automated single cell-ICP-ToF-MS

  • Diatoms are located at the bottom of the food chain. Toxicological relevant metals can possibly accumulate within the food web and cause harmful effects. Diatoms are a test system in ecotoxicology. Toxicological effects weaken the growth of algae which is by default investigated by means of fluorescence detection. On basis of the expose concentration as well as obtained fluorescence data potential threshold exceedance in e.g. surface waters is assessed. However, this approach does not allow for the determination of “real” accumulated metal concentration in diatoms. Common approaches are based on bulk analysis via e.g. ICP-MS, ICP-OES or AAS. But, biological variability is completely disregarded. To tackle this problem, alternative approaches are highly needed. Within the last years, sp-ICP-MS for nanoparticle as well as single cell analysis turned out as a powerful technique to analyze metal contents as well as size distributions on broad size range. But, common ICP-MS systems do notDiatoms are located at the bottom of the food chain. Toxicological relevant metals can possibly accumulate within the food web and cause harmful effects. Diatoms are a test system in ecotoxicology. Toxicological effects weaken the growth of algae which is by default investigated by means of fluorescence detection. On basis of the expose concentration as well as obtained fluorescence data potential threshold exceedance in e.g. surface waters is assessed. However, this approach does not allow for the determination of “real” accumulated metal concentration in diatoms. Common approaches are based on bulk analysis via e.g. ICP-MS, ICP-OES or AAS. But, biological variability is completely disregarded. To tackle this problem, alternative approaches are highly needed. Within the last years, sp-ICP-MS for nanoparticle as well as single cell analysis turned out as a powerful technique to analyze metal contents as well as size distributions on broad size range. But, common ICP-MS systems do not allow for multi-element detection within single particle/cell events. Thus, simultaneous MS detection devices are needed - just recently, ICP-ToF-MS experienced a revival. Within our previous work, we developed an automated sample introduction system based on a HPLC system on-line with single particle-ICP-MS, which allowed for ionic background separation and single algae analysis. However, for unambiguous tracing several fingerprint elements and multielement analysis in single algae (diatoms) is needed. Thus, we coupled our previous setup on-line to ICP-ToF-MS. Test diatom species were exposed to test substances (Zn) as well as nanoparticles (FeNPs). The developed setup allowed for a fast, automated and multielement analysis in single diatoms. Furthermore, we combined our approach with multivariate data assessment - multielement detection of characteristic fingerprint elements allowed for an unambiguous diatom tracing. Clustering of diatoms according to metal exposure concentration levels was enabled. Our approach is a new potential tool in ecotoxicological testing.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • DGMS_2020_Meermann.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Björn MeermannORCiD
Koautor*innen:Marcus Von der Au, O. Borovinskaya, C. Büchel
Dokumenttyp:Vortrag
Veröffentlichungsform:Präsentation
Sprache:Englisch
Jahr der Erstveröffentlichung:2020
Organisationseinheit der BAM:1 Analytische Chemie; Referenzmaterialien
1 Analytische Chemie; Referenzmaterialien / 1.1 Anorganische Spurenanalytik
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Sanitär- und Kommunaltechnik; Umwelttechnik
Freie Schlagwörter:Diatoms; New ecotoxicological testing tools; Single cell-ICP-ToF-MS
Themenfelder/Aktivitätsfelder der BAM:Chemie und Prozesstechnik
Chemie und Prozesstechnik / Chemische Charakterisierung und Spurenanalytik
Umwelt
Veranstaltung:53. DGMS & 27th ICP-MS user meeting
Veranstaltungsort:Münster, Germany
Beginndatum der Veranstaltung:01.03.2020
Enddatum der Veranstaltung:04.03.2020
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:17.04.2020
Referierte Publikation:Nein
Eingeladener Vortrag:Nein
Einverstanden