Das Suchergebnis hat sich seit Ihrer Suchanfrage verändert. Eventuell werden Dokumente in anderer Reihenfolge angezeigt.
  • Treffer 10 von 42
Zurück zur Trefferliste

Performance of a polycapillary halflens as focussing and collecting optic - a comparison

  • Polycapillary halflenses are widely used to focus X-ray radiation onto a small spot. Additionally they can reduce the field of view of a semiconductor detector when placed in front of one. In 3D micro X-ray fluorescence spectroscopy (3D Micro-XRF) with synchrotron radiation, two polycapillary halflenses are used in a confocal geometry. Up until now, characterization measurements in the focal plane have only been performed in the case of the lens focusing parallel radiation. Assumptions have been made, that in the other case, when isotropic radiation from a spot source is transported to a detector, the acceptance distribution in the focal plane is also Gaussian. We performed measurements with an electron beam as well as a proton beam which confirm this assumption. In addition, a comparison between measurements in collecting and focusing mode show differences in spot size and transmission. These differences exemplify the fact that there is not one global spot size or transmissionPolycapillary halflenses are widely used to focus X-ray radiation onto a small spot. Additionally they can reduce the field of view of a semiconductor detector when placed in front of one. In 3D micro X-ray fluorescence spectroscopy (3D Micro-XRF) with synchrotron radiation, two polycapillary halflenses are used in a confocal geometry. Up until now, characterization measurements in the focal plane have only been performed in the case of the lens focusing parallel radiation. Assumptions have been made, that in the other case, when isotropic radiation from a spot source is transported to a detector, the acceptance distribution in the focal plane is also Gaussian. We performed measurements with an electron beam as well as a proton beam which confirm this assumption. In addition, a comparison between measurements in collecting and focusing mode show differences in spot size and transmission. These differences exemplify the fact that there is not one global spot size or transmission function of a polycapillary halflens. Illumination and divergence effects can alter both characteristic lens parameters.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Timo Wolff, I. Mantouvalou, W. Malzer, J. Nissen, D. Berger, I. Zizak, D. Sokaras, A. Karydas, N. Grlj, P. Pelicon, R. Schütz, M. Zitniki, B. Kanngießer
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Journal of analytical atomic spectrometry
Jahr der Erstveröffentlichung:2009
Verlag:Royal Society of Chemistry
Verlagsort:London
Jahrgang/Band:24
Erste Seite:669
Letzte Seite:675
DOI:10.1039/b817828c
ISSN:0267-9477
ISSN:1364-5544
Verfügbarkeit des Dokuments:Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")
Bibliotheksstandort:Sonderstandort: Publica-Schrank
Datum der Freischaltung:19.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:26.05.2009
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.