Radiographic modelling for NDE of subsea pipelines

  • This work presents an investigation of the accuracy of a radiographic simulation model applied to subsea pipeline inspections. Experimental measurements of a sample in a water tank are used to develop a set of calibrated simulation parameters for the modelling software aRTist. Image quality parameters such as signal-tonoise ratio, contrast and basic spatial resolution are compared with the aim of matching simulated values to experimental results. With this method signal-to-noise ratio was successfully matched while differences were still found in contrast-to-noise ratio comparisons. This means that measurements depending on absolute intensity are not accurate enough, however wall thickness measurements in tangential images, which are not based on absolute intensity, were found to produce similar results in simulated and experimental cases. The differences in contrast and intensity are thought to be due to detector backscatter and additional scatter from out-of-setup objects within theThis work presents an investigation of the accuracy of a radiographic simulation model applied to subsea pipeline inspections. Experimental measurements of a sample in a water tank are used to develop a set of calibrated simulation parameters for the modelling software aRTist. Image quality parameters such as signal-tonoise ratio, contrast and basic spatial resolution are compared with the aim of matching simulated values to experimental results. With this method signal-to-noise ratio was successfully matched while differences were still found in contrast-to-noise ratio comparisons. This means that measurements depending on absolute intensity are not accurate enough, however wall thickness measurements in tangential images, which are not based on absolute intensity, were found to produce similar results in simulated and experimental cases. The differences in contrast and intensity are thought to be due to detector backscatter and additional scatter from out-of-setup objects within the exposure bay, due to a lack of source collimation. These would affect the experimental results but were not included in the simulated setup. This was investigated by including different proportions of peripheral water and other objects in the modelled setup and examining the effect on Image quality parameters. Results show that this additional scatter has a significant impact on the radiograph, particularly on image contrast, and is therefore the likely cause of differences between experimental and simulated images. This implies that it will be very difficult to completely match simulated to experimental results, as including all possible scattering objects in the model would be very complex. An improvement could be made by using real subsea data to estimate this additional scattering, which could then be used to calibrate the model. However there would still be significant uncertainty in the ability of the model to accurately produce realistic intensity and contrast.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Haith-2017-Radiographic-modelling-NDE-subsea-pipelines-NDTE.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:M. I. Haith, Uwe Ewert, Stefan Hohendorf, Carsten BellonORCiD, Andreas Deresch, P. Huthwaite, M. J. S. Lowe, Uwe ZscherpelORCiD
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):NDT&E International
Jahr der Erstveröffentlichung:2017
Jahrgang/Band:86
Erste Seite:113
Letzte Seite:122
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Freie Schlagwörter:Digital radiography; Modelling validation; Subsea pipeline inspection; Tangential radiography
DOI:10.1016/j.ndteint.2016.11.006
ISSN:0963-8695
ISSN:1879-1174
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:30.01.2017
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:23.03.2017
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.