FEA of the mechanical response of installed impact target foundations in drop tests of dangerous goods packagings

  • Packagings for the transport of dangerous goods need to meet special requirements to get an approval. This includes free fall drop testing onto an essentially unyielding surface as a means to assess a package’s resistance to mechanical damage. A main requirement for drop tests is that the impact target’s mass shall be at least 50 times that of the heaviest package to be tested. Nevertheless, many manufacturers do not possess foundation structures with the required mass ratio. Previous evidence highlights that the mass ratio is not a decisive criterion on its own. Parameters such as the impact target foundation’s connection and the impulse experienced by the impacting object are essential as well. However, these factors are not easily verifiable since experimental measurements are not possible at most facilities. The objective of this work is to provide a detailed analysis on the interaction between impact target foundation and subgrade in dynamic impact testing using validatedPackagings for the transport of dangerous goods need to meet special requirements to get an approval. This includes free fall drop testing onto an essentially unyielding surface as a means to assess a package’s resistance to mechanical damage. A main requirement for drop tests is that the impact target’s mass shall be at least 50 times that of the heaviest package to be tested. Nevertheless, many manufacturers do not possess foundation structures with the required mass ratio. Previous evidence highlights that the mass ratio is not a decisive criterion on its own. Parameters such as the impact target foundation’s connection and the impulse experienced by the impacting object are essential as well. However, these factors are not easily verifiable since experimental measurements are not possible at most facilities. The objective of this work is to provide a detailed analysis on the interaction between impact target foundation and subgrade in dynamic impact testing using validated finite-element (FE) models. This research is highly beneficial for industrial application since it allows manufacturers to make informed predictions about the mechanical response of installed impact target foundations.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • B07-1461_Poster-Lengas.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Nikolaos Lengas, Karsten Müller, Eva Schlick-Hasper, Marcel Neitsch, Sergej Johann, M. W. Zehn
Dokumenttyp:Posterpräsentation
Veröffentlichungsform:Präsentation
Sprache:Englisch
Jahr der Erstveröffentlichung:2023
Organisationseinheit der BAM:3 Gefahrgutumschließungen; Energiespeicher
3 Gefahrgutumschließungen; Energiespeicher / 3.1 Sicherheit von Gefahrgutverpackungen und Batterien
8 Zerstörungsfreie Prüfung
8 Zerstörungsfreie Prüfung / 8.1 Sensorik, mess- und prüftechnische Verfahren
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurwissenschaften und zugeordnete Tätigkeiten
Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurbau
Freie Schlagwörter:Dangerous goods packagings; Drop test; Foundation; Structural dynamics
Themenfelder/Aktivitätsfelder der BAM:Infrastruktur
Veranstaltung:FEMS EUROMAT 2023
Veranstaltungsort:Frankfurt a. M., Germany
Beginndatum der Veranstaltung:03.09.2012
Enddatum der Veranstaltung:07.09.2023
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:12.09.2023
Referierte Publikation:Nein
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.