The quantification of hydrogen and methane in contaminated groundwater: validation of robust procedures for sampling and quantification

  • A number of currently recommended sampling techniques for the determination of hydrogen in contaminated groundwater were compared regarding the practical proficiency in field campaigns. Key characteristics of appropriate sampling procedures are reproducibility of results, robustness against varying field conditions such as hydrostatic pressure, aquifer flow, and biological activity. Laboratory set-ups were used to investigate the most promising techniques. Bubble stripping with gas sampling bulbs yielded reproducible recovery of hydrogen and methane which could be verified for groundwater sampled in two field campaigns. The methane content of the groundwater was confirmed by analysis of directly pumped samples thus supporting the trueness of the stripping results. Laboratory set-ups and field campaigns revealed that bubble stripping of hydrogen may be restricted to the type of used pump. Concentrations of dissolved hydrogen after bubble stripping with an electrically driven submersibleA number of currently recommended sampling techniques for the determination of hydrogen in contaminated groundwater were compared regarding the practical proficiency in field campaigns. Key characteristics of appropriate sampling procedures are reproducibility of results, robustness against varying field conditions such as hydrostatic pressure, aquifer flow, and biological activity. Laboratory set-ups were used to investigate the most promising techniques. Bubble stripping with gas sampling bulbs yielded reproducible recovery of hydrogen and methane which could be verified for groundwater sampled in two field campaigns. The methane content of the groundwater was confirmed by analysis of directly pumped samples thus supporting the trueness of the stripping results. Laboratory set-ups and field campaigns revealed that bubble stripping of hydrogen may be restricted to the type of used pump. Concentrations of dissolved hydrogen after bubble stripping with an electrically driven submersible pump were about one order of magnitude higher than those obtained from diffusion sampling. The gas chromatographic determination for hydrogen and methane requires manual injection of gas samples and detection by a pulsed discharge detector (PDD) and allows limits of quantification of 3 nM dissolved hydrogen and 1 µg L-1 dissolved methane in groundwater. The combined standard uncertainty of the bubble stripping and GC/PDD quantification of hydrogen in field samples was 7% at 7.8 nM and 18% for 78 nM.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Ute Dorgerloh, Roland Becker, H. Theißen, Irene Nehls
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Journal of environmental monitoring
Jahr der Erstveröffentlichung:2010
Verlag:Royal Society of Chemistry
Verlagsort:Cambridge
Jahrgang/Band:12
Ausgabe/Heft:10
Erste Seite:1876
Letzte Seite:1884
DOI:10.1039/c0em00091d
ISSN:1464-0325
ISSN:1464-0333
Verfügbarkeit des Dokuments:Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")
Bibliotheksstandort:Sonderstandort: Publica-Schrank
Datum der Freischaltung:19.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:27.10.2010
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.