• Treffer 1 von 8
Zurück zur Trefferliste

Coherence preservation and beam flatness of a single-bounce multilayer monochromator (beamline ID19-ESRF)

  • Larger spectral bandwidth and higher photon flux density are the major advantages of multilayer monochromators over crystal-based devices. Especially for synchrotron-based hard X-ray microimaging applications the increased photon flux density is important in order to achieve high contrast and resolution in space and/or time. However, the modifications on the beam profile induced by reflection on a multilayer are a drawback which can seriously harm the performance of such a monochromator. A recent study [A. Rack, T. Weitkamp, M. Riotte, D. Grigoriev, T. Rack, L. Helfen, T. Baumbach, R. Dietsch, T. Holz, M. Krämer, F. Siewert, M. Meduna, P. Cloetens, E. Ziegler, J. Synchrotron Radiat. 17 (2010) 496–510] has shown that the modifications in terms of beam flatness and coherence preservation can be influenced via the material composition of the multilayer coating. The present article extends this knowledge by studying further material compositions used on a daily basis for hard X-rayLarger spectral bandwidth and higher photon flux density are the major advantages of multilayer monochromators over crystal-based devices. Especially for synchrotron-based hard X-ray microimaging applications the increased photon flux density is important in order to achieve high contrast and resolution in space and/or time. However, the modifications on the beam profile induced by reflection on a multilayer are a drawback which can seriously harm the performance of such a monochromator. A recent study [A. Rack, T. Weitkamp, M. Riotte, D. Grigoriev, T. Rack, L. Helfen, T. Baumbach, R. Dietsch, T. Holz, M. Krämer, F. Siewert, M. Meduna, P. Cloetens, E. Ziegler, J. Synchrotron Radiat. 17 (2010) 496–510] has shown that the modifications in terms of beam flatness and coherence preservation can be influenced via the material composition of the multilayer coating. The present article extends this knowledge by studying further material compositions used on a daily basis for hard X-ray monochromatization at the beamline ID19 of the European Synchrotron Radiation Facility.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • 1-s2.0-S016890021002560X-main.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:A. Rack, T. Weitkamp, I. Zanette, C. Morawe, A. Vivo Rommeveaux, P. Tafforeau, P. Cloetens, E. Ziegler, T. Rack, A. Cecilia, P. Vagovic, E. Harmann, R. Dietsch, Heinrich Riesemeier
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Nuclear instruments and methods in physics research A
Jahr der Erstveröffentlichung:2011
Verlag:Elsevier B.V.
Verlagsort:Amsterdam
Jahrgang/Band:649
Ausgabe/Heft:1
Erste Seite:123
Letzte Seite:127
Freie Schlagwörter:Coherence; Multilayer mirrors; Synchrotron radiation; X-ray imaging; X-ray monochromators; X-ray optics; X-ray phase contrast; X-rays
DOI:10.1016/j.nima.2010.11.069
ISSN:0168-9002
ISSN:0167-5087
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")