Determination of the Effective Detector Area of an Energy-Dispersive X-Ray Spectrometer at the Scanning Electron Microscope Using Experimental and Theoretical X-Ray Emission Yields

  • A method is proposed to determine the effective detector area for energy-dispersive X-ray spectrometers (EDS). Nowadays, detectors are available for a wide range of nominal areas ranging from 10 up to 150mm2. However, it remains in most cases unknown whether this nominal area coincides with the “net active sensor area” that should be given according to the related standard ISO 15632, or with any other area of the detector device. Moreover, the specific geometry of EDS installation may further reduce a given detector area. The proposed method can be applied to most scanning electron microscope/EDS configurations. The basic idea consists in a comparison of the measured count rate with the count rate resulting from known X-ray yields of copper, titanium, or silicon. The method was successfully tested on three detectors with known effective area and applied further to seven spectrometers from different manufacturers. In most cases the method gave an effective area smaller than the areaA method is proposed to determine the effective detector area for energy-dispersive X-ray spectrometers (EDS). Nowadays, detectors are available for a wide range of nominal areas ranging from 10 up to 150mm2. However, it remains in most cases unknown whether this nominal area coincides with the “net active sensor area” that should be given according to the related standard ISO 15632, or with any other area of the detector device. Moreover, the specific geometry of EDS installation may further reduce a given detector area. The proposed method can be applied to most scanning electron microscope/EDS configurations. The basic idea consists in a comparison of the measured count rate with the count rate resulting from known X-ray yields of copper, titanium, or silicon. The method was successfully tested on three detectors with known effective area and applied further to seven spectrometers from different manufacturers. In most cases the method gave an effective area smaller than the area given in the detector description.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Procop_Determination of the Effective Detector Area.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Mathias ProcopORCiD, Vasile-Dan HodoroabaORCiD, R. Terborg, D. Berger
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Microscopy and Microanalysis
Jahr der Erstveröffentlichung:2016
Verlag:Cambridge University Press
Verlagsort:New York, NY, USA
Jahrgang/Band:22
Ausgabe/Heft:6
Erste Seite:1360
Letzte Seite:1368
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Freie Schlagwörter:EDX; Effective area; Energy-dispersive X-ray spectrometer (EDS); Geometrical collection efficiency; X-ray emission yield
DOI:10.1017/S1431927616011788
URL:https://www.cambridge.org/core/journals/microscopy-and-microanalysis/article/div-classtitledetermination-of-the-effective-detector-area-of-an-energy-dispersive-x-ray-spectrometer-at-the-scanning-electron-microscope-using-experimental-and-theoretical-x-ray-emission-yieldsdiv/E15B2E67C349201CF323E778EB9C6D94
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:02.01.2017
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:10.03.2017
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.