Determination of Cr(VI) in wood specimen: A XANES study at the Cr K edge
- The content of chromium in different oxidation states in chromium-treated wood was studied with XANES (X-ray absorption near-edge structure) measurements at the Cr K absorption edge. It could be shown that wood samples treated with Cr(VI) (pine and beech) did still contain a measurable content of Cr(VI) after four weeks conditioning. If such wood samples were heat exposed for 2 h with 135 °C prior conditioning, Cr(VI) was no longer detected by XANES, indicating a complete reduction to chromium (III).
Autor*innen: | Erik Strub, Rüdiger Plarre, Martin RadtkeORCiD, Uwe Reinholz, Heinrich Riesemeier, Ute Schoknecht, Klaus Urban, P. Jüngel |
---|---|
Dokumenttyp: | Zeitschriftenartikel |
Veröffentlichungsform: | Verlagsliteratur |
Sprache: | Englisch |
Titel des übergeordneten Werkes (Englisch): | Nuclear instruments and methods in physics research B |
Jahr der Erstveröffentlichung: | 2008 |
Verlag: | Elsevier |
Verlagsort: | Amsterdam |
Jahrgang/Band: | 266 |
Ausgabe/Heft: | 10 |
Erste Seite: | 2405 |
Letzte Seite: | 2407 |
Freie Schlagwörter: | Reduction; Specifikation; X-ray spectroscopy; XANES; XAS; XRF |
DOI: | 10.1016/j.nimb.2008.03.011 |
ISSN: | 0168-583X |
ISSN: | 1872-9584 |
Verfügbarkeit des Dokuments: | Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access") |
Bibliotheksstandort: | Sonderstandort: Publica-Schrank |
Datum der Freischaltung: | 19.02.2016 |
Referierte Publikation: | Ja |
Datum der Eintragung als referierte Publikation: | 05.06.2008 |