Additively manufactured Flow Cells for Inline Mixing and Reaction Monitoring with Low-Field NMR Spectroscopy

  • The demand for increasing product diversity in the chemical process industry calls for new production processes that enable greater flexibility. Therefore, plants are needed that produce significant quantities for market supply that can be scaled up to several tons per year. Compared to traditional batch processes, intensified continuous production enables not only flexibility but also the production of compounds that are difficult to produce. Custom-designed small-scale reactors significantly improve heat and mass transfer through micro mixing and can improve safety, e.g. in the case of high grade exothermic or high-pressure reactions, and might play an important role for customized, modular production facilities.1 Combined with optimally designed flow cells, compact NMR instruments currently present promising analytical tools for use in flow chemistry applications.2,3 In recent process monitoring applications, the flow cell and the mixing unit are usually separated parts leading to aThe demand for increasing product diversity in the chemical process industry calls for new production processes that enable greater flexibility. Therefore, plants are needed that produce significant quantities for market supply that can be scaled up to several tons per year. Compared to traditional batch processes, intensified continuous production enables not only flexibility but also the production of compounds that are difficult to produce. Custom-designed small-scale reactors significantly improve heat and mass transfer through micro mixing and can improve safety, e.g. in the case of high grade exothermic or high-pressure reactions, and might play an important role for customized, modular production facilities.1 Combined with optimally designed flow cells, compact NMR instruments currently present promising analytical tools for use in flow chemistry applications.2,3 In recent process monitoring applications, the flow cell and the mixing unit are usually separated parts leading to a severe time delay between mixing and first data acquisition. In this work, we present a comprehensive workflow for the design of a flow cell−mixer combination based on CFD simulation and other design principles.4 Due to the increasing opportunities in additive manufacturing of ceramics, it was possible to realize an optimized SMX-type mixer with a fully integrated NMR flow cell (cf. Fig. 1). Validation studies exhibited 1H NMR spectra with a quality comparable to common NMR glass tubes. So far, the mixing performance of the system has been evaluated for different mass flow rates within the intended working range of 5–120 seconds region and compared to ideally mixed samples. Thus, the integrated flow cell−static mixer combination can be used for different purposes such as evaluation of fluid properties, equilibration studies, or reaction monitoring of two instantaneously mixed samples. The ceramic flow cell was additively manufactured and analyzed through x-ray microtomography revealing surface characteristics due to the manufacturing process (cf. Fig. 2). Furthermore, the working range of the whole system was characterized leading to an operational specification for further applications. In summary, the role of custom-designed components for modular, chemical production, amongst other essential factors like fast development of reliable evaluation models is discussed. References [1] Bornemann-Pfeiffer et al., Chem. Ing. Tech. (2021), 93: 1–10 [2] Kern et al., Anal. Bioanal. Chem. (2018) 410: 3349–3360 [3] Kern et al., Anal. Bioanal. Chem. (2019) 411: 3037–3046 [4] Bornemann et al., Ind. Eng. Chem. Res. (2019), 58: 19562−19570zeige mehrzeige weniger

Volltext Dateien herunterladen

  • v2_2021-11-17_Europact_Bornemann.pdf
    deu

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Martin Bornemann-PfeifferORCiD
Koautor*innen:S. Kern, N. Jurtz, T. Thiede, M. Kraume, Michael Maiwald
Dokumenttyp:Vortrag
Veröffentlichungsform:Präsentation
Sprache:Deutsch
Jahr der Erstveröffentlichung:2021
Organisationseinheit der BAM:1 Analytische Chemie; Referenzmaterialien
1 Analytische Chemie; Referenzmaterialien / 1.4 Prozessanalytik
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Freie Schlagwörter:Additive manufacturing; Computational fluid dynamics; NMR spectroscopy; Process analytical technology
Themenfelder/Aktivitätsfelder der BAM:Chemie und Prozesstechnik
Veranstaltung:EUROPACT - European Conference on Process Analytics and Control Technology
Veranstaltungsort:Online meeting
Beginndatum der Veranstaltung:15.11.2021
Enddatum der Veranstaltung:17.11.2021
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:24.11.2021
Referierte Publikation:Nein
Eingeladener Vortrag:Nein
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.