Statistical comparison of various reconstruction algorithms with respect to missing wedge artifacts in computed tomography

  • The presence of elongation, streak and blurring artifacts in tomograms recorded under a missing wedge of rotation angles presents a major challenge for the quantitative analysis of tomographic image data. We show that the missing wedge artifacts of standard reconstruction algorithms may be reduced by the innovative reconstruction technique DIRECTT. For the comparison of missing wedge artifacts we apply techniques from spatial statistics, which have been specifically designed to investigate the shape of phase boundaries in tomograms.

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:S. Lueck, Andreas KupschORCiD, Axel Lange, Manfred P. Hentschel, V. Schmidt
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Materials research society symposium proceedings
Jahr der Erstveröffentlichung:2012
Herausgeber (Institution):Materials Research Society
Verlag:North-Holland Publ. Co.
Verlagsort:New York, NY
Jahrgang/Band:1421
Erste Seite:1
Letzte Seite:6
Freie Schlagwörter:Scanning transmission electron microscopy (STEM); Structural; X-ray tomography
DOI:10.1557/opl.2012.209
ISSN:0272-9172
Verfügbarkeit des Dokuments:Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")
Bibliotheksstandort:Sonderstandort: Publica-Schrank
Datum der Freischaltung:19.02.2016
Referierte Publikation:Nein
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.