Ringversuche zur Einführung von Geruchsmessungen in die Bewertung von Bauprodukten entsprechend der DIN ISO 16000-28 und VDI 4302-1
- The DIN ISO 16000-28 and VDI 4302-1 describe a method for the assessment of the perceived intensity of odours. It is based on a trained assessment panel using a referencing scale that provides defined acetone concentrations. Due to the AgBB-scheme including a place holder for odour assessment it is currently checked whether the method is applicable.
To check the applicability a pilot phase regarding the „Implementation of Odour Measurements into the Assessment of Building Products“ was started by AgBB1 in 2012. Düring this phase amongst others two interlaboratory tests were conducted. The first one in 2012 served to test the applicability and to identify need and potential for improvement. Based on those findings an additional Standard Operation procedure was developed for the second interlaboratory test in 2014.
The second interlaboratory test confirmed the findings of the first one and the need for improvement of the measurement method as well. Nonetheless both tests showedThe DIN ISO 16000-28 and VDI 4302-1 describe a method for the assessment of the perceived intensity of odours. It is based on a trained assessment panel using a referencing scale that provides defined acetone concentrations. Due to the AgBB-scheme including a place holder for odour assessment it is currently checked whether the method is applicable.
To check the applicability a pilot phase regarding the „Implementation of Odour Measurements into the Assessment of Building Products“ was started by AgBB1 in 2012. Düring this phase amongst others two interlaboratory tests were conducted. The first one in 2012 served to test the applicability and to identify need and potential for improvement. Based on those findings an additional Standard Operation procedure was developed for the second interlaboratory test in 2014.
The second interlaboratory test confirmed the findings of the first one and the need for improvement of the measurement method as well. Nonetheless both tests showed Standard deviations of reproducibility between 20 and 40%. Standard deviations of reproducibility of well-established interlaboratory tests for VOCs show comparable results.…
MetadatenAutor*innen: | Laura Brosig, Wolfgang HornORCiD, Oliver Jann |
---|
Dokumenttyp: | Beitrag zu einem Tagungsband |
---|
Veröffentlichungsform: | Graue Literatur |
---|
Sprache: | Deutsch |
---|
Titel des übergeordneten Werkes (Deutsch): | 17. Workshop - Geruch und Emissionen bei Kunststoffen |
---|
Jahr der Erstveröffentlichung: | 2015 |
---|
Erste Seite: | 8-1 |
---|
Letzte Seite: | 8-9 |
---|
Veranstaltung: | 17. Workshop - Geruch und Emissionen bei Kunststoffen |
---|
Veranstaltungsort: | Kassel, Germany |
---|
Beginndatum der Veranstaltung: | 16.03.2015 |
---|
Enddatum der Veranstaltung: | 17.03.2015 |
---|
Verfügbarkeit des Dokuments: | Datei im Netzwerk der BAM verfügbar ("Closed Access") |
---|
Datum der Freischaltung: | 20.02.2016 |
---|
Referierte Publikation: | Nein |
---|