Das Suchergebnis hat sich seit Ihrer Suchanfrage verändert. Eventuell werden Dokumente in anderer Reihenfolge angezeigt.
  • Treffer 81 von 139
Zurück zur Trefferliste

Evaluation of self-heating in Miscanthus x giganteus energy crop clamps and the implications for harvesting time

  • Miscanthus x giganteus energy crop grown in Ireland was harvested on 21st of February and 28th of March 2012 to examine the effects of harvesting time on self-heating during storage of Miscanthus chips in clamps (98 m³) under weather sheltered conditions. There was a relatively large difference in moisture content, of 21.4%, between Miscanthus crop harvested in February and March (41.6 and 20.2%, respectively). Temperature evolution over a storage period of up to 125 days was monitored at different heights and distances from the centre within the clamps. Maximum temperature in the February constructed clamp reached 69 °C compared to 28 °C in the March constructed clamp. Microbial activity was monitored via carbon dioxide and oxygen gas measurements. The high moisture clamp showed higher microbial activity and a volume yield loss of 4.3% due to decomposition in the top section of the clamp. Quality indices post-storage were also assessed. Calorific values from Miscanthus sampled 1 mMiscanthus x giganteus energy crop grown in Ireland was harvested on 21st of February and 28th of March 2012 to examine the effects of harvesting time on self-heating during storage of Miscanthus chips in clamps (98 m³) under weather sheltered conditions. There was a relatively large difference in moisture content, of 21.4%, between Miscanthus crop harvested in February and March (41.6 and 20.2%, respectively). Temperature evolution over a storage period of up to 125 days was monitored at different heights and distances from the centre within the clamps. Maximum temperature in the February constructed clamp reached 69 °C compared to 28 °C in the March constructed clamp. Microbial activity was monitored via carbon dioxide and oxygen gas measurements. The high moisture clamp showed higher microbial activity and a volume yield loss of 4.3% due to decomposition in the top section of the clamp. Quality indices post-storage were also assessed. Calorific values from Miscanthus sampled 1 m below the top surface were similar after storage for both February and March constructed clamps, i.e. 18.52 and 18.70 MJ kg-1, respectively. A reliable assessment of self-heating in Miscanthus chip clamps has important consequences for both self-ignition risk and biomass quality.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • 1-s2.0-S0360544213005203-main.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:C.D. Everard, J. Finnan, K.P. McDonnell, Martin Schmidt
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Energy
Jahr der Erstveröffentlichung:2013
Verlag:Elsevier
Verlagsort:Amsterdam [u.a.]
Jahrgang/Band:58
Erste Seite:350
Letzte Seite:356
Freie Schlagwörter:Biomass quality; Biomass storage; Miscanthus x giganteus; Self-heating; Self-ignition
DOI:10.1016/j.energy.2013.06.022
ISSN:0360-5442
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:20.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:12.09.2013
Einverstanden