• Treffer 103 von 160
Zurück zur Trefferliste

Probability of defect detection of Posiva's electron beam weld

  • The report 'Probability of Defect Detection of Posiva's electron beam weld' describes POD curves of four NDT methods radiographic testing, ultrasonic testing, eddy current testing and visual testing. POD-curves are based on the artificial defects in reference blocks. The results are devoted to the demonstration of suitability of the methods for EB weld testing. Report describes methodology and procedure applied by BAM. Report creates a link from the assessment of the reliability and inspection performance to the risk assessment process of the canister final disposal project. Report ensures the confirmation of the basic quality of the NDT methods and their capability to describe the quality of the EB-weld. The probability of detection curves are determined based on the MIL-1823 standard and it's reliability guidelines. The MIL-1823 standard was developed for the determination of integrity of gas turbine engines for the US military. In the POD-process there are determined as a keyThe report 'Probability of Defect Detection of Posiva's electron beam weld' describes POD curves of four NDT methods radiographic testing, ultrasonic testing, eddy current testing and visual testing. POD-curves are based on the artificial defects in reference blocks. The results are devoted to the demonstration of suitability of the methods for EB weld testing. Report describes methodology and procedure applied by BAM. Report creates a link from the assessment of the reliability and inspection performance to the risk assessment process of the canister final disposal project. Report ensures the confirmation of the basic quality of the NDT methods and their capability to describe the quality of the EB-weld. The probability of detection curves are determined based on the MIL-1823 standard and it's reliability guidelines. The MIL-1823 standard was developed for the determination of integrity of gas turbine engines for the US military. In the POD-process there are determined as a key parameter for the defect detectability the a90/95 magnitudes, i.e. the size measure a of the defect, for which the lower 95 % confidence band crosses the 90 % POD level. By this way can be confirmed that defects with a size of a90/95 will be detected with 90 % probability. In case the experiment will be repeated 5 % might fall outside this confidence limit.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • WR_2013-70.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Daniel Kanzler, Christina Müller, J. Pitkänen
Dokumenttyp:Forschungsbericht
Veröffentlichungsform:Graue Literatur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Working Report 2013-70
Jahr der Erstveröffentlichung:2013
Erste Seite:1
Letzte Seite:86
Freie Schlagwörter:EB-welding; Eddy current inspection; NDT-methods; POD-curves; Probability of detection curves; Radiographic inspection; Ultrasonic inspection; Visual inspection
URL:http://www.posiva.fi/en/databank/working_reports/probability_of_defect_detection_of_posiva_s_electron_beam_weld.1874.xhtml?xm_col_report_year=2013&xm_col_language=3&xm_col_type=5&cd_order=col_report_number&cd_offset=0#.VJAIY3uj_mc
URL:http://www.posiva.fi/files/3527/WR_2013-70.pdf
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:20.02.2016
Referierte Publikation:Nein
Einverstanden