• Treffer 7 von 10
Zurück zur Trefferliste

Practical tests with R290 used in reefer container refrigeration -leakage testing-

  • The option of using flammable refrigerants in the reefer container has already been studied and reported by König (2013, 2014) in various publications. In the present paper, the results of experiments are presented, related to the investigation of the potential fire and explosions risks by R290 leaks in refrigerated containers. A safety concept for reefer containers operating with R290 as refrigerant has been tested and validated. In addition, there were extensive leakage simulations, the results have been evaluated for the comparison with the practical tests. Both experiments and the simulations were done at the Federal Institute for Materials Research and Testing (BAM). Further tests are carried out by the manufacturer with the support of the firefighting service and the Danish institute of Fire and Security Technology (DBI). The results from practical tests and the leakage simulations allow for first generalization and more precise studies with respect to potential risks ofThe option of using flammable refrigerants in the reefer container has already been studied and reported by König (2013, 2014) in various publications. In the present paper, the results of experiments are presented, related to the investigation of the potential fire and explosions risks by R290 leaks in refrigerated containers. A safety concept for reefer containers operating with R290 as refrigerant has been tested and validated. In addition, there were extensive leakage simulations, the results have been evaluated for the comparison with the practical tests. Both experiments and the simulations were done at the Federal Institute for Materials Research and Testing (BAM). Further tests are carried out by the manufacturer with the support of the firefighting service and the Danish institute of Fire and Security Technology (DBI). The results from practical tests and the leakage simulations allow for first generalization and more precise studies with respect to potential risks of refrigerant leaks. Potentially explosive atmospheres situations can be evaluated much easier and appropriate measures can be derived. It turns out that dangerous situations for small, medium and rupture of pipe leaks are manageable. The results of the practical testing of leaking R290 inside and outside of a reefer container showed that the risk is being commonly overestimated.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Holtappels GL 2016 Tests with R290 in reefer container.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:H. König
Koautor*innen:Kai Holtappels, M. Bararu
Dokumenttyp:Vortrag
Veröffentlichungsform:Präsentation
Sprache:Englisch
Jahr der Erstveröffentlichung:2016
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurbau
Freie Schlagwörter:Explosion tests; Gas dispersion; Leakage tests; Reefer container; Safety concept
Veranstaltung:12th IIR Gustav Lorentzen Conference on Natural Refrigerants
Veranstaltungsort:Glasgow, UK
Beginndatum der Veranstaltung:21.08.2016
Enddatum der Veranstaltung:24.08.2016
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:09.12.2016
Referierte Publikation:Nein
Eingeladener Vortrag:Nein
Einverstanden