• Treffer 1 von 2
Zurück zur Trefferliste

Impact-Echo Dataset "IE Platte"

  • This dataset contains raw data resulting from Impact-Echo measurements at the reference concrete block "IE Platte", located at BAM (German Federal Institute for Materials Research and Testing). The specimen contains three polystyrene slabs and one polyethylene foil to act as reflectors. The specimen was produced in a three-step process. First, the base plate was cast. Second, the reflectors were taped to the base plate. Finally, the upper layer was cast on top of base plate and reflectors. A drawing is contained in the dataset. The Impact-Echo method is based on the excitation of the zero-group-velocity frequency of the first symmetric Lamb mode of a plate-like structure, in order to assess its thickness. Numerous publications elaborate on Impact-Echo theory, examples are (Gibson and Popovics 2005, Schubert and Köhler 2008 , Abraham and Popovics 2010). The measurements have been conducted using a setup that contains only commercially available components. The setup consists ofThis dataset contains raw data resulting from Impact-Echo measurements at the reference concrete block "IE Platte", located at BAM (German Federal Institute for Materials Research and Testing). The specimen contains three polystyrene slabs and one polyethylene foil to act as reflectors. The specimen was produced in a three-step process. First, the base plate was cast. Second, the reflectors were taped to the base plate. Finally, the upper layer was cast on top of base plate and reflectors. A drawing is contained in the dataset. The Impact-Echo method is based on the excitation of the zero-group-velocity frequency of the first symmetric Lamb mode of a plate-like structure, in order to assess its thickness. Numerous publications elaborate on Impact-Echo theory, examples are (Gibson and Popovics 2005, Schubert and Köhler 2008 , Abraham and Popovics 2010). The measurements have been conducted using a setup that contains only commercially available components. The setup consists of an Olson CTG-2 concrete thickness gauge (Olsen Instruments, USA) for actuation and sensing and an 8-bit NI USB-5132 digital storage oscilloscope (National Instruments, USA) combined with the Echolyst software (Schweizerischer Verein für technische Inspektionen (SVTI), Switzerland) for data acquisition. Measurements were conducted using a grid of 29x29 points with a spacing of 50 mm. At each point 8192 samples were recorded at a sampling rate of 1 MS/s. The dataset contains the (X,Y) location in mm of the individual measurement points as well as the raw measurement data at those points. The data is provided in the formats *.mir/*.mhdr (Echolyst), *.npy (Python) and *.mat (Matlab) and *.csv to ease the import in various post-processing tools.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Bjarne Grotelüschen, Benjamin BühlingORCiD
Dokumenttyp:Forschungsdatensatz
Veröffentlichungsform:Graue Literatur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Harvard Dataverse Repository
Jahr der Erstveröffentlichung:2022
Organisationseinheit der BAM:8 Zerstörungsfreie Prüfung
8 Zerstörungsfreie Prüfung / 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen
Herausgeber (Institution):Bundesanstalt für Materialforschung und -prüfung (BAM)
Verlag:Harvard College
Verlagsort:Cambridge, MA, USA
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Freie Schlagwörter:Concrete; Impact-Echo; Nondestructive testing
Themenfelder/Aktivitätsfelder der BAM:Chemie und Prozesstechnik
Art der Ressource:Datensatz
Ort der Datenerhebung:Berlin, Germany
DOI:10.7910/DVN/EH4E9G
Beschreibung der Datei(en) :The original Echolyst data in *.mir/*.mhdr formats has been converted to *.csv, *.npy and *.mat using the Python csv, numpy and scipy libraries, respectively.In the original data, the first measurement point is located at (x,y) = (0,0) mm. In the conversion, this is corrected to fit the specimen coordinate system, i.e. all points are shifted by (x,y) = (50,50) mm, since the true first point was located 50 mm from the specimen edges, not directly on the specimen corner.
Verfügbarkeit des Dokuments:Datei für die Öffentlichkeit verfügbar ("Open Access")
Lizenz (Deutsch):License LogoCreative Commons - CC0 1.0 - Universell - Public Domain Dedication
Datum der Freischaltung:18.07.2022
Referierte Publikation:Nein
Schriftenreihen ohne Nummerierung:Forschungsdatensätze der BAM
Einverstanden