XCT simulation: Effects of error sources on dimensional measurements for medical and standard objects
- The quantification of experimental and data analysis errors is most of the times jeopardised by the presence of surface roughness, waviness, as well as by typical measurement artefacts of the XCT technique (for instance refraction at sharp edges). One way to at least estimate the influence of those factors on dimensional measurements and on tolerances is to simulate them using Monte-Carlo method. An alternative strategy is to use independent knowledge (e.g. CMM data) to smoothen/calibrate/correct XCT data.
Autor*innen: | Fabien LéonardORCiD |
---|---|
Dokumenttyp: | Vortrag |
Veröffentlichungsform: | Präsentation |
Sprache: | Englisch |
Jahr der Erstveröffentlichung: | 2019 |
Organisationseinheit der BAM: | 8 Zerstörungsfreie Prüfung |
8 Zerstörungsfreie Prüfung / 8.5 Röntgenbildgebung | |
DDC-Klassifikation: | Naturwissenschaften und Mathematik / Chemie / Analytische Chemie |
Freie Schlagwörter: | Beam hardening; Part geometry; Part material; Partial volume effect; aRTist |
Themenfelder/Aktivitätsfelder der BAM: | Chemie und Prozesstechnik |
Veranstaltung: | Workshop on additive manufacturing |
Veranstaltungsort: | Berlin, Germany |
Beginndatum der Veranstaltung: | 13.05.2019 |
Verfügbarkeit des Dokuments: | Datei im Netzwerk der BAM verfügbar ("Closed Access") |
Datum der Freischaltung: | 21.06.2019 |
Referierte Publikation: | Nein |
Eingeladener Vortrag: | Nein |