Power-to-Gas: Safety Characteristics of Hydrogen/NaturalGas-Mixtures

  • Safety characteristics for explosion protection of natural gas/hydrogen mixtures relevant in connection with the Power2Gas technology were studied in this work. Lower explosion limits (LEL) and upper explosion limits (UEL), limiting oxygen concentrations (LOC), maximum experimental safety gaps (MESG), maximum explosion pressures (pmax) and maximum rates of pressure rise (dp/dt)max were determined experimentally in dependence of the hydrogen fraction. Adding hydrogen did mainly effect the UEL, LOC, MESG and (dp/dt)max. The mixtures become more "critical" concerning the explosion hazards with increasing hydrogen fraction. However, the dependency of the safety characteristics from the hydrogen fraction is mainly not linear. Adding up to 10% hydrogen to natural gas had nearly no effect on the safety characteristics. More significant effects on the safety characteristics were observed at hydrogen fractions of more than 25%. For example the explosion group changes from IIA to IIB.Safety characteristics for explosion protection of natural gas/hydrogen mixtures relevant in connection with the Power2Gas technology were studied in this work. Lower explosion limits (LEL) and upper explosion limits (UEL), limiting oxygen concentrations (LOC), maximum experimental safety gaps (MESG), maximum explosion pressures (pmax) and maximum rates of pressure rise (dp/dt)max were determined experimentally in dependence of the hydrogen fraction. Adding hydrogen did mainly effect the UEL, LOC, MESG and (dp/dt)max. The mixtures become more "critical" concerning the explosion hazards with increasing hydrogen fraction. However, the dependency of the safety characteristics from the hydrogen fraction is mainly not linear. Adding up to 10% hydrogen to natural gas had nearly no effect on the safety characteristics. More significant effects on the safety characteristics were observed at hydrogen fractions of more than 25%. For example the explosion group changes from IIA to IIB. Considering the huge explosion region and very high (dp/dt)max of hydrogen compared to natural gas, even adding 50% hydrogen to natural gas has a rather small effect on these characteristics. Furthermore pmax of hydrogen/natural-gas mixtures can be calculated with good accuracy assuming ideal adiabatic conditions. EL and LOC of natural gas/hydrogen mixtures in ternary systems with inert gas and air were calculated in dependence of the type of inert gas with the so called “model of constant adiabatic flame temperature profiles”.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Askar_Power to Gas.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Enis AskarORCiD, Volkmar Schröder, A. Seemann, S. Schuetz
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Chemical Engineering Transactions
Jahr der Erstveröffentlichung:2016
Verlag:AIDIC
Jahrgang/Band:2016/48
Erste Seite:397
Letzte Seite:402
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Angewandte Physik
Freie Schlagwörter:Energy storage; Explosion protection; Hydrogen enriched natural gas; Hydrogen safety
DOI:10.3303/CET1648067
ISSN:2283-9216
ISBN:78-88-95608-39-6
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:07.07.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:24.10.2016
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.