1st international round robin test on safety characteristics of hybrid mixtures

  • There is no applicable existing standard for the determination of safety characteristics for hybrid mixtures. While developing a new standard in a joint research project in Germany first results from parameter studies led to a standard procedure that can be adopted by laboratories that are already testing dusts in the so called 20L-sphere with as little additional effort as necessary. In fact, one of the main objectives of this research project was to keep modifications and adjustments from the generally accepted dust testing procedures as easy and minimal as possible so as to limit potential deviations from one laboratory to another. In this first round robin test on hybrid mixtures ever, with methane as gas component and a specific corn starch as dust sample, the practicality of the whole procedure, the scattering of the results and the deviation between the testing apparatuses is investigated. This paper summarizes the experimental procedure adopted and objectives of the firstThere is no applicable existing standard for the determination of safety characteristics for hybrid mixtures. While developing a new standard in a joint research project in Germany first results from parameter studies led to a standard procedure that can be adopted by laboratories that are already testing dusts in the so called 20L-sphere with as little additional effort as necessary. In fact, one of the main objectives of this research project was to keep modifications and adjustments from the generally accepted dust testing procedures as easy and minimal as possible so as to limit potential deviations from one laboratory to another. In this first round robin test on hybrid mixtures ever, with methane as gas component and a specific corn starch as dust sample, the practicality of the whole procedure, the scattering of the results and the deviation between the testing apparatuses is investigated. This paper summarizes the experimental procedure adopted and objectives of the first round-robin phase involving three of the four original German companies, plus volunteering laboratories from Australia, Belgium, Czech Republic, France, Poland and P.R. China. The results will have an impact on the new standard and may lead to robust data for later simulation purposes.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Spitzer_et_al_2022.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Stefan SpitzerORCiD, Enis AskarORCiD, Alexander Benke, C. Cloney, S. D’Hyon, O. Dufaud, Z. Dyduch, D. Gabel, P. Geoerg, V. Heilmann, V. Jankuj, W. Jian, U. Krause, Arne Krietsch, M. Mynarz, F. Norman, J. Skrinsky, J. Taveau, A. Vignes, S. Zakel, S. Zhong
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Journal of loss prevention in the process industries
Jahr der Erstveröffentlichung:2022
Organisationseinheit der BAM:2 Prozess- und Anlagensicherheit
2 Prozess- und Anlagensicherheit / 2.1 Sicherheit von Energieträgern
Verlag:Elsevier
Verlagsort:Amsterdam
Jahrgang/Band:81
Aufsatznummer:104947
Erste Seite:1
Letzte Seite:8
DDC-Klassifikation:Technik, Medizin, angewandte Wissenschaften / Ingenieurwissenschaften / Ingenieurbau
Freie Schlagwörter:20L-sphere; Hybrid mixtures; Round robin test; Turbulent combustion
Themenfelder/Aktivitätsfelder der BAM:Infrastruktur
DOI:10.1016/j.jlp.2022.104947
ISSN:0950-4230
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:12.12.2022
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:18.01.2023
Paper des Monats:Ja
Einverstanden