Catalyst as ignition source of an explosion inside a microreactor
- The present issue reports on a specific aspect of safety engineering of the heterogeneously catalysed oxidation of ethene in a continuous-flow microreactor. Conversion of ethene and the corresponding surface temperature of the catalyst were monitored for different reactor temperatures and total flow rates with a stoichiometric ethene/oxygen mixture for total oxidation. Safe operation of the highly exothermic oxidation was possible, but not in the whole parameter range. At high reactor temperatures and flow rates, ignition of an explosion inside the microreactor caused by a hot spot on the surface of the catalyst was observed for the first time.
Autor*innen: | Sebastian Heinrich, Florian Edeling, Christian Liebner, Hartmut Hieronymus, T. Lange, E. Klemm |
---|---|
Dokumenttyp: | Zeitschriftenartikel |
Veröffentlichungsform: | Verlagsliteratur |
Sprache: | Englisch |
Titel des übergeordneten Werkes (Englisch): | Chemical engineering science |
Jahr der Erstveröffentlichung: | 2012 |
Verlag: | Elsevier |
Verlagsort: | Amsterdam |
Jahrgang/Band: | 84 |
Erste Seite: | 540 |
Letzte Seite: | 543 |
Freie Schlagwörter: | Catalyst; Ethene; Explosions; Hot spot; Microstructure; Safety |
DOI: | 10.1016/j.ces.2012.08.049 |
ISSN: | 0009-2509 |
Verfügbarkeit des Dokuments: | Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access") |
Bibliotheksstandort: | Sonderstandort: Publica-Schrank |
Datum der Freischaltung: | 19.02.2016 |
Referierte Publikation: | Ja |
Datum der Eintragung als referierte Publikation: | 25.10.2012 |