VOC emissions from building materials accompanying sensory tests for different evaluation schemes

  • Within a follow up project of a former study (Horn et al. 2005) emissions and odor from different types of construction products were investigated (financed by the German Federal Environmental Agency - FKZ 37 07 62 300). The tested materials were mainly those used for construction of floors indoors. For this type of materials in Germany several labeling procedures exist which are based on Emission chamber testing. Two important labeling procedures in Germany are based on the AgBBevaluation scheme (Däumling et al. 2005). For some applications (flooring material) it is the mandatory Ü-mark of DIBt (German Institute for Construction Technology). Furthermore for carpets, adhesives and many other products, like sealants, mattresses, furniture and so on the voluntary blue angel mark exist. Within this scheme the volatile organic compounds (VOC) compounds are measured with well established procedures and are evaluated with LCI-values which were derived from health information. Beyond thatWithin a follow up project of a former study (Horn et al. 2005) emissions and odor from different types of construction products were investigated (financed by the German Federal Environmental Agency - FKZ 37 07 62 300). The tested materials were mainly those used for construction of floors indoors. For this type of materials in Germany several labeling procedures exist which are based on Emission chamber testing. Two important labeling procedures in Germany are based on the AgBBevaluation scheme (Däumling et al. 2005). For some applications (flooring material) it is the mandatory Ü-mark of DIBt (German Institute for Construction Technology). Furthermore for carpets, adhesives and many other products, like sealants, mattresses, furniture and so on the voluntary blue angel mark exist. Within this scheme the volatile organic compounds (VOC) compounds are measured with well established procedures and are evaluated with LCI-values which were derived from health information. Beyond that many complaints according to building products are caused by odors. Therefore an evaluation procedure for the odor is very important and should be implemented into all of the mentioned labeling schemes.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • VOC emissions from building.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Wolfgang HornORCiD, B. Müller, J. Panaskova, Oliver Jann, W. Plehn, D. Müller
Dokumenttyp:Beitrag zu einem Tagungsband
Veröffentlichungsform:Graue Literatur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Indoor Air 2011, 12th International conference on indoor air quality and climate (Proceedings)
Jahr der Erstveröffentlichung:2011
Herausgeber (Institution):International society of indoor air quality and climate (ISIAQ)
Ausgabe/Heft:Paper 768
Erste Seite:1
Letzte Seite:2
Freie Schlagwörter:AgBB; Construction product; Evaluation; Odor; VOC-emission
Veranstaltung:Indoor Air 2011, 12th International conference on indoor air quality and climate
Veranstaltungsort:Austin, TX, USA
Beginndatum der Veranstaltung:05.06.2011
Enddatum der Veranstaltung:10.06.2011
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:19.02.2016
Referierte Publikation:Nein