Das Suchergebnis hat sich seit Ihrer Suchanfrage verändert. Eventuell werden Dokumente in anderer Reihenfolge angezeigt.
  • Treffer 10 von 78
Zurück zur Trefferliste

Heavy metal removal from sewage sludge ash analyzed by thermogravimetry

  • A high temperature (1000 °C) thermochemical process for heavy metal removal from sewage sludge ash via the chloride pathway was investigated by thermogravimetry/differential thermal analysis (TG/DTA). TG and DTA measurements gave information about secession and evaporation of water, HCl, and heavy metal chlorides at different temperatures. Additionally, gaseous water and hydrochloric acid which occurred in the process were detected by an FT-IR detector that was coupled to the TG/DTA-system. Heavy metal chlorides which were also formed in the process cannot be detected by this technique. For that reason the outlet gas of the TG/DTA-system was discharged into washing flasks filled with water for absorption. The washing flasks were replaced in temperature steps of 50 °C and the heavy metal concentrations of the solutions were determined by ICP-OES. The temperature-dependent formation/evaporation of different heavy metal chlorides was analyzed and compared for two different thermochemicalA high temperature (1000 °C) thermochemical process for heavy metal removal from sewage sludge ash via the chloride pathway was investigated by thermogravimetry/differential thermal analysis (TG/DTA). TG and DTA measurements gave information about secession and evaporation of water, HCl, and heavy metal chlorides at different temperatures. Additionally, gaseous water and hydrochloric acid which occurred in the process were detected by an FT-IR detector that was coupled to the TG/DTA-system. Heavy metal chlorides which were also formed in the process cannot be detected by this technique. For that reason the outlet gas of the TG/DTA-system was discharged into washing flasks filled with water for absorption. The washing flasks were replaced in temperature steps of 50 °C and the heavy metal concentrations of the solutions were determined by ICP-OES. The temperature-dependent formation/evaporation of different heavy metal chlorides was analyzed and compared for two different thermochemical processes using magnesium chloride hydrate or calcium chloride hydrate as Cl-donors. In both cases evaporation of Cd, Cu, Pb, and Zn was observed from 600 °C, whereas As, Cr, and Ni remained in the solid state. The results were discussed against the background of thermodynamic calculations.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • 10.1007_s10973-010-0966-7.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Christian VogelORCiD, Christian AdamORCiD, M. Unger
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Journal of thermal analysis and calorimetry
Jahr der Erstveröffentlichung:2011
Verlag:Kluwer Academic Publ.
Verlagsort:Dordrecht
Jahrgang/Band:103
Erste Seite:243
Letzte Seite:248
Freie Schlagwörter:Heavy metal chloride; Sewage sludge ash; Thermodynamic simulation; Thermogravimetry/FT-IR
DOI:10.1007/s10973-010-0966-7
ISSN:1388-6150
ISSN:1418-2874
ISSN:0368-4466
ISSN:1572-8943
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:19.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:07.02.2011
Einverstanden