Das Suchergebnis hat sich seit Ihrer Suchanfrage verändert. Eventuell werden Dokumente in anderer Reihenfolge angezeigt.
  • Treffer 61 von 96
Zurück zur Trefferliste

Safe product design - the role of the NDE reliability analysis

  • When pushed to the limits of their detection capability, NDE systems do not produce consistent hit/miss indications. Their capability of detecting small defects is therefore expressed in terms of POD. An adequate NDE system is required to ensure the structural integrity. In conventional signal response analysis, the POD is expressed as a function of the defect size, and its adequacy for the inspection task is tested against the maximum allowable defect size which will not undermine the structural integrity. Analyses of modern structures show that other parameters, beside the defect size, can both significantly influence the POD and determine the severity of the defect for the structure. Within the multi-parameter reliability analysis, the POD is expressed as a function of those influencing parameters. When determining the adequacy of the NDE system, the capability of detecting a defect has to be expressed and tested against the critical value of exactly that parameter that determinesWhen pushed to the limits of their detection capability, NDE systems do not produce consistent hit/miss indications. Their capability of detecting small defects is therefore expressed in terms of POD. An adequate NDE system is required to ensure the structural integrity. In conventional signal response analysis, the POD is expressed as a function of the defect size, and its adequacy for the inspection task is tested against the maximum allowable defect size which will not undermine the structural integrity. Analyses of modern structures show that other parameters, beside the defect size, can both significantly influence the POD and determine the severity of the defect for the structure. Within the multi-parameter reliability analysis, the POD is expressed as a function of those influencing parameters. When determining the adequacy of the NDE system, the capability of detecting a defect has to be expressed and tested against the critical value of exactly that parameter that determines defects severity for the structure. Failing to do so can lead to a rejection of the healthy, or acceptance of the bad part. The principle is demonstrated on the example of the Transmit-Receive Longitudinal (TRL) ultrasonic inspection of the iron cast component for semi-elliptical surface defects.zeige mehrzeige weniger

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Mato Pavlovic, U. Ronneteg, Christina Müller, Uwe Ewert, C. Boller
Dokumenttyp:Beitrag zu einem Tagungsband
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):18th WCNDT - World conference on nondestructive testing (Proceedings)
Jahr der Erstveröffentlichung:2012
Erste Seite:1
Letzte Seite:9 (Paper 310)
Freie Schlagwörter:Multi-parameter; Probability of detection (POD); Reliability; Transmit receive longitudinal (TRL); Ultrasonics
Veranstaltung:18th WCNDT - World conference on nondestructive testing
Veranstaltungsort:Durban, South Africa
Beginndatum der Veranstaltung:2012-04-16
Enddatum der Veranstaltung:2012-04-20
ISBN:978-0-620-52872-6
Verfügbarkeit des Dokuments:Physisches Exemplar in der Bibliothek der BAM vorhanden ("Hardcopy Access")
Bibliotheksstandort:Sonderstandort: Publica-Schrank
Datum der Freischaltung:20.02.2016
Referierte Publikation:Nein
Einverstanden