• Treffer 36 von 65
Zurück zur Trefferliste

Nondestructive insights into composition of the sculpture of Egyptian Queen Nefertiti with CT and the dependence of object surface from image processing

  • Precautions in the generation of surfaces from CT images should be the rule. Two different data sets of the bust of Nefertiti and additional data from an industrial CT scanner will show the conflicts that arise when defining a surface. The recent trend in CT is to extract surfaces from CT measurements which can compete with the accuracy of tactile measurements. As CT is complicated by artefacts, a lot of precautions need to be taken in order to get exact results. More errors are introduced, if the surface of an object made from different dense materials is calculated. A publication in April 2009 of "Radiology" dealt with the surface of the stone behind the stucco layer of the famous bust of the Egyptian Queen Nefertiti in the Ägytische Museum Berlin. Using this data, we will show the different problems that arise from inadequate image processing. Furthermore, a detailed comparison of the two CT measurements made 14 years apart is given. Conclusions: Respect the traps in virtualPrecautions in the generation of surfaces from CT images should be the rule. Two different data sets of the bust of Nefertiti and additional data from an industrial CT scanner will show the conflicts that arise when defining a surface. The recent trend in CT is to extract surfaces from CT measurements which can compete with the accuracy of tactile measurements. As CT is complicated by artefacts, a lot of precautions need to be taken in order to get exact results. More errors are introduced, if the surface of an object made from different dense materials is calculated. A publication in April 2009 of "Radiology" dealt with the surface of the stone behind the stucco layer of the famous bust of the Egyptian Queen Nefertiti in the Ägytische Museum Berlin. Using this data, we will show the different problems that arise from inadequate image processing. Furthermore, a detailed comparison of the two CT measurements made 14 years apart is given. Conclusions: Respect the traps in virtual imaging.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • illerhaus.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Bernhard Illerhaus, Andreas Staude, Dietmar Meinel
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Graue Literatur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):The e-journal of nondestructive testing & ultrasonics
Jahr der Erstveröffentlichung:2009
Verlag:NDT.net
Verlagsort:Kirchwald
Jahrgang/Band:14
Ausgabe/Heft:9
Aufsatznummer:8043
Erste Seite:1
Letzte Seite:11
Freie Schlagwörter:Computertomographie; Oberfläche; Oberflächenbestimmung
Artifacts; Computed X ray tomography; Image processing (computer-assisted); Implants
URL:https://www.ndt.net/search/docs.php3?id=8043
ISSN:1435-4934
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:19.02.2016
Referierte Publikation:Nein
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.