Influence of operating conditions on the fluidic ultrasonic transducer signal

  • While contact and immersion ultrasonic testing are established methods in non-destructive testing (NDT), generating high power air-coupled ultrasound remains a challenging task. Solutions often involve setups that are restricted to lab environments. When field measurements are required, such as in NDT for civil engineering, a handy, robust and safe transducer is needed. For this purpose, an ultrasonic transducer based on a fluidic switch has been developed. A sonic air flow inside the device is switched rapidly so that an ultrasonic signal is generated. Both theory and previous flow simulations suggest that the control flow pressure ramp has only little influence on the switching time of the device. This publication gives an overview over the operating principle of the fluidic ultrasonic transducer and investigates the influence of control tube length and pulsing repetition rate on the ultrasonic pressure amplitude. High repetition rates are found to reduce the signal amplitude,While contact and immersion ultrasonic testing are established methods in non-destructive testing (NDT), generating high power air-coupled ultrasound remains a challenging task. Solutions often involve setups that are restricted to lab environments. When field measurements are required, such as in NDT for civil engineering, a handy, robust and safe transducer is needed. For this purpose, an ultrasonic transducer based on a fluidic switch has been developed. A sonic air flow inside the device is switched rapidly so that an ultrasonic signal is generated. Both theory and previous flow simulations suggest that the control flow pressure ramp has only little influence on the switching time of the device. This publication gives an overview over the operating principle of the fluidic ultrasonic transducer and investigates the influence of control tube length and pulsing repetition rate on the ultrasonic pressure amplitude. High repetition rates are found to reduce the signal amplitude, whereas long tubing has only little negative influence on the amplitude while improving signal quality.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Buehling_2021_Inluence_of_Operating_Conditions_on_the_Fluidic_Ultrasonic_Transducer_Signal.pdf
    eng

    Article

  • daga21_Inhaltsverzeichnis.pdf
    deu

    Table of contents of the conference proceedings

  • daga21_Impressum_und_Hinweis_auf_Zweitveroeffentlichungsrecht.pdf
    deu

    Imprint and reference to secondary publication rights

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:Benjamin BühlingORCiD, T. Schweitzer, Stefan MaackORCiD, Christoph StrangfeldORCiD
Dokumenttyp:Beitrag zu einem Tagungsband
Veröffentlichungsform:Graue Literatur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Fortschritte der Akustik - DAGA 2021
Jahr der Erstveröffentlichung:2021
Organisationseinheit der BAM:8 Zerstörungsfreie Prüfung
8 Zerstörungsfreie Prüfung / 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen
Herausgeber (Institution):Deutsche Gesellschaft für Akustik e.V. (DEGA)
Verlagsort:Berlin, Germany
Erste Seite:48
Letzte Seite:51
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Freie Schlagwörter:Fluidic devices; Non-destructive testing; Ultrasound
Themenfelder/Aktivitätsfelder der BAM:Chemie und Prozesstechnik
Veranstaltung:47. Jahrestagung für Akustik (DAGA 2021)
Veranstaltungsort:Vienna, Austria
Beginndatum der Veranstaltung:15.08.2021
Enddatum der Veranstaltung:18.08.2021
URL:https://pub.dega-akustik.de/DAGA_2021
ISBN:978-3-939296-18-8
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:11.10.2021
Referierte Publikation:Nein
Einverstanden