CCQM-K143 Comparison of Copper Calibration Solutions Prepared by NMIs/DIs

  • CCQM-K143 is a key comparison that assesses participants’ ability to prepare single element calibration solutions. Preparing calibration solutions properly is the cornerstone of establishing a traceability link to the International System of Units (SI), and therefore should be tested in order to confirm the validity of CCQM comparisons of more complex materials. CCQM-K143 consisted of participants each preparing a single copper calibration solution at 10 g/kg copper mass fraction and shipping 10 bottled aliquots of that solution to the coordinating laboratory, the National Institute of Standards and Technology (NIST). The masses and mass fraction for the prepared solutions were documented with the submitted samples. The solutions prepared by all participants were measured at NIST by high performance inductively coupled plasma optical emission spectroscopy (HP-ICP-OES). The intensity measurements for copper were not mapped onto values of mass fraction via calibration. Instead, ratiosCCQM-K143 is a key comparison that assesses participants’ ability to prepare single element calibration solutions. Preparing calibration solutions properly is the cornerstone of establishing a traceability link to the International System of Units (SI), and therefore should be tested in order to confirm the validity of CCQM comparisons of more complex materials. CCQM-K143 consisted of participants each preparing a single copper calibration solution at 10 g/kg copper mass fraction and shipping 10 bottled aliquots of that solution to the coordinating laboratory, the National Institute of Standards and Technology (NIST). The masses and mass fraction for the prepared solutions were documented with the submitted samples. The solutions prepared by all participants were measured at NIST by high performance inductively coupled plasma optical emission spectroscopy (HP-ICP-OES). The intensity measurements for copper were not mapped onto values of mass fraction via calibration. Instead, ratios were computed between the measurements for copper and simultaneous measurements for manganese, the internal standard, and all subsequent data reductions, including the computation of the KCRV and the degrees of equivalence, were based on these ratios. Other than for two participants whose measurement results appeared to suffer from calculation or preparation errors, all unilateral degrees of equivalence showed that the measured values did not differ significantly from the KCRV. These results were confirmed by a second set of ICP-OES measurements performed by the Physikalisch-Technische Bundesanstalt (PTB). CCQM-K143 showed that participants are capable of preparing calibration solutions starting from high purity, assayed copper metal. Similar steps are involved when preparing solutions for other elements, so it seems safe to infer that similar capabilities should prevail when preparing many different, single-element solutions.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Molloy-et-al_CCQM-K143-copper-calibration-solutions_Metrologia-2020.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:J. L. Molloy, M. R. Winchester, T. A. Butler, A. M. Possolo, O. Rienitz, A. Roethke, V. Goerlitz, R. Caciano de Sena, M. Dominguez Almeida, L. Yang, B. Methven, K. Nadeau, P. Romero Arancibia, W. Bing, Z. Tao, J. Snell, Jochen VoglORCiD, Maren Koenig, R. K. Kotnala, S. Swarupa Tripathy, C. Elishian, R. Ketrin, T. Suzuki, T. Oduor Okumu, Y.-H. Yim, S. W. Heo, H. S. Min, M. Sub Han, Y. Lim, J. Velina Lara Manzano, F. Segoviano Regalado, M. Arvizu Torres, E. Valle Moya, M. Buzoianu, A. Sobina, V. Zyskin, E. Sobina, P. Migal, M. Linsky, S. Z. Can, B. Ari, H. Goenaga Infante
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Metrologia
Jahr der Erstveröffentlichung:2020
Organisationseinheit der BAM:1 Analytische Chemie; Referenzmaterialien
1 Analytische Chemie; Referenzmaterialien / 1.1 Anorganische Spurenanalytik
Verlag:IOP Science
Verlagsort:Cambridge
Jahrgang/Band:58
Ausgabe/Heft:1A
Erste Seite:08006
DDC-Klassifikation:Naturwissenschaften und Mathematik / Chemie / Analytische Chemie
Freie Schlagwörter:Metrology; Primary calibration solution; Traceability
Themenfelder/Aktivitätsfelder der BAM:Chemie und Prozesstechnik
DOI:10.1088/0026-1394/58/1A/08006
ISSN:0026-1394
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:13.01.2021
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:30.12.2021
Einverstanden
Diese Webseite verwendet technisch erforderliche Session-Cookies. Durch die weitere Nutzung der Webseite stimmen Sie diesem zu. Unsere Datenschutzerklärung finden Sie hier.