Das Suchergebnis hat sich seit Ihrer Suchanfrage verändert. Eventuell werden Dokumente in anderer Reihenfolge angezeigt.
  • Treffer 6 von 7
Zurück zur Trefferliste

Development of ELISA methodologies for the direct determination of 17beta-estradiol and 17alpha-ethinylestraydiol in complex aqueous matrices

  • This study comprises the development of enzyme-linked immunosorbent assays (ELISAs) for the quantification of 17β-estradiol (E2) and 17α-ethinylestradiol (EE2) in complex aqueous matrices without any sample clean-up procedures. Salinity and dissolved organic matter were selected as potential interfering agents in the analysis of E2 and EE2. The optimization was performed in order to (i) overcome matrix effects, and to (ii) increase sensitivity. The addition of a sample buffer containing bovine serum albumin (BSA) prior to the sample was found to decrease the influence of matrix effects. Moreover, adjustments of this buffer's pH together with the optimization of tracer (T) dilution and incubation time were undertaken in order to lower the quantification range. The optimized methods allowed the quantification of E2 and EE2 in the ranges 0.03–200 µg L-1 and 0.02–10 µg L-1, respectively. The assays were applied to real aqueous samples. It was possible to do a first approach to the levelsThis study comprises the development of enzyme-linked immunosorbent assays (ELISAs) for the quantification of 17β-estradiol (E2) and 17α-ethinylestradiol (EE2) in complex aqueous matrices without any sample clean-up procedures. Salinity and dissolved organic matter were selected as potential interfering agents in the analysis of E2 and EE2. The optimization was performed in order to (i) overcome matrix effects, and to (ii) increase sensitivity. The addition of a sample buffer containing bovine serum albumin (BSA) prior to the sample was found to decrease the influence of matrix effects. Moreover, adjustments of this buffer's pH together with the optimization of tracer (T) dilution and incubation time were undertaken in order to lower the quantification range. The optimized methods allowed the quantification of E2 and EE2 in the ranges 0.03–200 µg L-1 and 0.02–10 µg L-1, respectively. The assays were applied to real aqueous samples. It was possible to do a first approach to the levels of E2 in Portuguese surface and waste waters; however, it was not feasible to detect EE2 in the samples tested.zeige mehrzeige weniger

Volltext Dateien herunterladen

  • Development of ELISA methodologies.pdf
    eng

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Anzahl der Zugriffe auf dieses Dokument
Metadaten
Autor*innen:C.P. Silva, D.L.D. Lima, Rudolf SchneiderORCiD, M. Otero, V.I. Esteves
Dokumenttyp:Zeitschriftenartikel
Veröffentlichungsform:Verlagsliteratur
Sprache:Englisch
Titel des übergeordneten Werkes (Englisch):Journal of environmental management
Jahr der Erstveröffentlichung:2013
Verlag:Elsevier Ltd.
Verlagsort:Amsterdam
Jahrgang/Band:124
Erste Seite:121
Letzte Seite:127
Freie Schlagwörter:17alpha-Ethinylestradiol; 17beta-Estradiol; Endocrine disrupting compounds; Enzyme-linked immunosorbent assay; Surface water; Wastewater
DOI:10.1016/j.jenvman.2013.03.041
ISSN:0301-4797
ISSN:1095-8630
Verfügbarkeit des Dokuments:Datei im Netzwerk der BAM verfügbar ("Closed Access")
Datum der Freischaltung:20.02.2016
Referierte Publikation:Ja
Datum der Eintragung als referierte Publikation:27.05.2013